Connecting to the monitoring device, Fiber tap – Net Optics Fiber Taps User Manual
Page 10
Fiber Tap
6
Connecting to the Monitoring Device
1 . Connect to the Monitor Port using the included custom LC analyzer cable .
2. Connect one side of the twin-duplex fiber cable into a RX port on the
monitoring device to view one side of the full-duplex link .
3. Connect the other side of the twin-duplex fiber cable into another RX port
on the monitoring device to view the other side of the full-duplex link .
4 . Verify that the Tap Monitor Port is cabled to the monitoring device .
Note: ________________________________________________________________
The connectors on the twin-duplex side of the custom analyzer cable contain
RX connections only. The empty TX sides are present to eliminate cabling
errors and should also be connected to the monitoring device.
______________________________________________________________________
To Monitoring Device
A
B
A
A
B
B
OUT
OUT
OUT
OUT
IN
IN
LASER
CAUTION!
Splitter Tap
Splitter Tap
www.netoptics.com
Figure 4:
Connecting the Monitoring Device (LC model shown)