C.6 tcp server mode operation troubleshooting, C.7 serial communication troubleshooting – SENA NEMO10-SK User Manual
Page 52

51
C.6 TCP Server Mode Operation Troubleshooting
Problem
Cause
Action
IP configuration of
remote host is invalid
Check if IP configuration of the remote host is valid
Host mode of the
NEMO10 serial port is
not TCP server
Change the host mode of the NEMO10 serial port to TCP server
or TCP server/client
IP address of the
NEMO10 or TCP port
number is wrong
Specify valid IP address and TCP port number of the NEMO10
DSR option is set but
DSR input is not high
Disable DSR option or make DSR input of the NEMO10 high
Cannot connect to
the NEMO10
TCP connection with
the other host is
established already
Close established TCP connection or connect later
C.7 Serial Communication Troubleshooting
Problem
Cause
Action
Serial data are not
transferred by
TCP/IP immediately
Too large inter-character
timeout
Set inter-character timeout with smaller value
Cannot
communicate with
the NEMO10
Invalid serial port
configuration
Check if serial port configuration of the NEMO10 are the same
with that of the serial device
Invalid data
transferred
Invalid serial port
configuration
Check if serial port configuration is correct.