Remote configuration, Software and utility, Paraniwin – SENA Parani-SD1100 User Manual
Page 16

16
3.8. Remote Configuration
Parani-SD1100 supports remote configuration. After connecting to the Parani-SD1100 through
Bluetooth, before sending any other character, send three escape character (default :+). Then, the
Parani-
SD1100 will enter remote configuration mode and print “Please Enter Password”. You have to
enter the password with “AT+PASS” command within 2 minutes. After the password authentication,
you are able to enter any at command except “ATH”, “ATO”, “ATD”, “AT+BTSCAN”, “AT+BTINQ?” and
“AT+BTCANCEL”. The default password is “0000” and it is configurable with “AT+CHPASS” command.
Example of remote configuration:
Example of remote configuration mode.
3.9. Software and Utility
This configuration software and utility for firmware update is included with the product, which also can
be downloaded from
Table 3-10 Configuration Software
Software
Purpose
Operating System
ParaniWIN
Configuration
MS Windows 98SE or Higher
ParaniMultiWizard
Multiple Connection Configuration
MS Windows 98SE or Higher
ParaniUpdater
Firmware Update
MS Windows 98SE or Higher
3.10. ParaniWIN
ParaniWIN is a program that runs on Microsoft Windows for the configuration of Parani-SD1100. Install
ParaniWIN on your computer. Plug a Parani-SD1100 into the serial port of the computer to use RS232
RS422/485 converter (SENA LTC 100) and turn on the power. Run ParaniWIN.
CONNECT 000195000001
+++
Please Enter Password
AT+PASS=0000
Remote Configuration Enabled
AT+BTINFO?
000195000001,SD1100v1.1.1-095515,MODE0,CONNECT,0,0,HWFC