Strong hg emission lines by wavelength (nm), Strong ar emission lines by wavelength (nm) – Ocean Optics HG-1 Mercury Argon User Manual
Page 5
![background image](/manuals/292551/5/background.png)
HG-1-CAL Installation and Operation Instructions
008-00000-STD-01-20100412
5
Strong Hg Emission Lines by Wavelength (nm)
There are more emission lines shown below than printed on the label on the HG-1 housing. The label
is intended as a quick, convenient reference and does not list every Ar and Hg emission line that
exists.
253.652
404.656
296.728
407.783*
302.150
435.833
313.155
546.074**
334.148
576.960
365.015
579.066
* This spectral line is not evident with spectrometers configured with 300 or 600 lines/mm gratings.
** Spectrometers with 1200, 1800, 2400 or 3600 lines/mm gratings have spectral lines evident at
576.96 nm and 579.07 nm.
Strong Ar Emission Lines by Wavelength (nm)
696.543
800.616*
706.722
811.531
714.704
826.452
727.294
842.465
738.398
852.144
750.387
866.794
763.511
912.297
772.376
922.450
794.818
* This spectral line is evident only with spectrometers configured with 1800, 2400, or 3600 lines/mm
gratings.
- Apex 785 Raman (1 page)
- STS-UV (2 pages)
- TR2 Engineering Note (4 pages)
- SAD500 Communications and Control (19 pages)
- Red Tide USB650 Install (26 pages)
- Fiber Optic Termination Kit (6 pages)
- Transmissive pH Probe (10 pages)
- Remora (42 pages)
- PlasCalc (59 pages)
- Correcting Device Driver Issues (8 pages)
- ecoVis Krypton Light Source (16 pages)
- LPC-500CM (28 pages)
- HPX-2000 (24 pages)
- ADC1000-USB (27 pages)
- Torus Operating Instructions (30 pages)
- ADC2000-PCI (13 pages)
- Sensors for Real-Time Analysis (2 pages)
- IDRaman reader (2 pages)
- DH-2000-CAL (30 pages)
- QE65 Pro (32 pages)
- Collimating Lenses (2 pages)
- D1000 (2 pages)
- IDRaman mini (2 pages)
- HR2000CG-UV-NIR (42 pages)
- Cool Red (1 page)
- HL-2000 (20 pages)
- XE-1 Xenon (6 pages)
- USB-ADP Serial Adapters (3 pages)
- CHEM2000 (36 pages)
- Deuterium-Halogen Calibration Light Source (19 pages)
- NeoFox Engineering Note (30 pages)
- QE Pro (2 pages)
- OOIBase32 (140 pages)
- AR-1 Argon (6 pages)
- pH Sensor Patches, Probes and Cuvettes (36 pages)
- SpecLine Offline Spectroscopy (60 pages)
- HL-2000-HP-232 (26 pages)
- External Triggering Options Instructions for Spectrometers with Firmware Version 3.0 and Above (16 pages)
- Breakout Box (10 pages)
- USB-ISS-UV_VIS (4 pages)
- ISS-UV_VIS (6 pages)
- OOIColor (14 pages)
- LS-1 Series (12 pages)
- Apex Install (24 pages)
- DH-2000 (34 pages)