beautypg.com

Dexter Laundry T-600 (30-Cycle) User Manual

Page 18

background image

18



For each number in the test, the function will be active when the START button
is pushed and will be inactive when the START button is released. Use the
SCROLL UP to move from one function to the next.

!

Step 1 - Lock the door.


!

Step 2 - Turn on thermoactuator #1 (lock).


!

Step 3 - Turn on thermoactuator #2 (unlock).


!

Step 4 - Close the drain valve.


!

Step 5 - Turn on the cold water to the tub.

The pressure switch low level setting can be tested at this point.
The drain valve is closed and cold water is on for as long as the
START button is pushed. When the water level reaches a low level,
the water valve will turn off and no additional cold water can be
added. (The time required to reach a low water is dependent on
input water pressure. It may require several minutes.)


!

Step 6 - Turn on the cold water to the dispenser.

The pressure switch low level setting can also be tested with this
step. For details see Step 5.


!

Step 7 - Turn on the hot water to the tub.

The pressure switch high level setting of the pressure switch can be
tested at this point. The drain valve is closed and hot water on
for as long as the START button is pushed. When the water level
reaches a high level, the water valve will turn off and no
additional hot water can be added. (The time required to reach a
high water is dependent on input water pressure. It may require
several minutes.)


!

Step 8 - Turn on the hot water to the dispenser.

The pressure switch high level setting can also be tested with this
step. For details see Step 7.


!

Step 9 - Forward tumble.


!

Step 10 - Reverse tumble.


!

Step 11 - Open drain.


!

Step 12 - Intermediate spin.

The I/O interface outputs labeled Reverse and Speed1 will be active
(the two RED LED=s will light).


!

Step 13 - Full speed spin.