7. Experiments

7.1 Lloyd’s

mirror

Fig. 4 Reflection from Lloyd’s mirror

Required:
1 Electronics board and plug-in power supply
1 Ultrasonic transmitter, 40 kHz
1 Microphone probe
1 Reflector
1 BNC/4-mm cable

Additionally required:
1 ESCOLA 10 multimeter

1006810

Connect the supplied plug-in transformer to

provide power to the equipment.

Connect the ultrasonic transmitter to Gen-

erator G1.

Connect the microphone probe to channel A

and set it up some distance in front of the

transmitter.

Connect the output of the channel to the

multimeter (measuring range: AC, 10 V).

Turn on the high-pass filter by means of
switch S1 (

) and set switch S2 to .

Set up the reflector parallel to the main

beam.

Change the distance of the reflector from the

main beam and observe the maxima and

minima in the measured sound amplitude.

Note: If the distance between the plane between
the transmitter and receiver and reflecting sur-
faces such as the base plate is equal to certain
specific values, then the direct beam and the
one reflected from the surface may be superim-
posed in such a way that destructive interfer-
ence ensues. With Lloyd’s mirror it is possible to
determine the minimum distance at which this
effect occurs. The effect does not occur at all if
the transmitter and receiver are set up so close
together on the base plate that they are nearer
to each other than this minimum distance.

7.2

Reflection from a convex mirror

Fig. 5 Reflection of a diverging sound beam by a

convex mirror

Required:
1 Electronics board and plug-in power supply
1 Ultrasonic transmitter, 40 kHz
1 Ultrasonic pen with holder
or

1 Microphone probe
1 Convex mirror
1 Absorber
1 BNC/4-mm cable

Additionally required:
1 ESCOLA 10 multimeter

1006810

Connect the supplied plug-in transformer to

provide power to the equipment.

Connect the ultrasonic transmitter to Gen-
erator G1.

Connect the ultrasonic pen, or alternatively a

microphone probe, to channel A and set it

up some distance in front of the transmitter.

Connect the output of the channel to the
multimeter (measuring range: AC, 10 V).

Turn on the high-pass filter by means of
switch S1 (

) and set switch S2 to .

Set up the convex mirror and point the
transmitter towards it.

Set up the reflector parallel to the direct

beam.

Find the optimum position for the receiver by

using a geometric construction and position
the ultrasonic pen at that point.

Move the ultrasonic pen until the received

signal is at a maximum.

Note: The alignment of the receiver and trans-
mitter with the convex mirror is comparable to a
domestic satellite dish.