5.4
Ultrasonic pen (including holder)
Warning:
The transducer in the ultrasonic pen
is sensitive to moisture and mechanical effects.
•
Do not subject the transducer to any me-
chanical stresses and do not let it come into
contact with liquids.
Ultrasonic probe with built-in transducer and
additional phase indicator in the form of an LED,
controlled by a current generated by the elec-
tronics board from the signal voltages of chan-
nels A and B. The brightness of the LED is re-
duced to a minimum when the phase difference
between the point where the measurement is
being made and a selected reference point is a
multiple of 360°.
The equipment can be held and moved by hand
or, in order to avoid interference from reflec-
tions, in the supplied holder.
Phase indicator input
(from channel A only): 0 … 15 mA (DC)
Frequency range:
1 Hz to 43 kHz
Output:
Signal for
channel A or B
Connectors:
3.5-mm jack plugs,
input: ring
output: tip
Cable length:
1 m approx.
Dimensions:
10 mm x 150 mm approx.
Weight:
32 g approx. without
holder
5.5 Convex
mirror
Transparent plastic convex mirror designed for
the space above a table top.
Focal length:
100 mm
Radius of curvature:
200 mm
Dimensions:
140 x 20 x 70 mm approx.
5.6 Fresnel
zone
plate
Plastic Fresnel zone plate designed for the
space above a table top.
Focal length:
35 mm
Dimensions:
140 x 20 x 50 mm approx.
5.7 Ultrasonic
absorber
Component for demonstrating sound insulation
or for suppressing sound travelling directly from
transmitter to microphone probe in some ex-
periments.
Surface: Fleece
textile
Dimensions:
80 x 15 x 50 mm approx.
5.8
Set for double slit
Set of equipment for setting up a double or sin-
gle slit or for use as individual reflectors or mir-
rors.
Surface:
Plastic coated
Dimensions:
100 x 20 x 50 mm approx.
or
20 x 20 x 50 mm approx.
5.9 Semi-transparent mirror (50%) and
Semi-transparent mirror (25%)
Partially transparent and partially reflecting mir-
rors made of perforated plastic (50%) or ex-
panded aluminium (25%).
Dimensions:
100 x 20 x 60 mm approx.
5.10 BNC
cable
For connecting amplifier outputs to an oscillo-
scope.
Cable length:
1 m approx.
5.11 BNC/4-mm
cable
For connecting amplifier outputs to an analog
voltmeter.
Cable length:
1 m approx.
5.12 Set of work templates
Work templates for experiments:
•
Diffraction at an edge
•
Propagation of waves beyond a slit
•
Diffraction by a double slit
•
Constructive und destructive interference
arising from diffraction by a double slit
•
Lloyd’s mirror
•
Set-up for a simple interferometer
•