Page 15: Owner’s manual
TR1616
Owner’s Manual
9
Any of the CAT5e cable configurations shown in the below table can be used when making BLU
link connections.
TIA/EIA 568A Straight Through
TIA/EIA 568B Straight Through
RJ-45
(8-Position)
RJ-45
(8-Position)
8
8
Brown
1
1
White / Green
2
2
Green
3
3
White / Orange
4
4
Blue
5
5
White / Blue
6
6
Orange
7
7
White / Brown
RJ-45
(8-Position)
RJ-45
(8-Position)
8
8
Brown
1
1
White / Orange
2
2
Orange
3
3
White / Green
4
4
Blue
5
5
White / Blue
6
6
Green
7
7
White / Brown
TIA/EIA 568A Crossover
TIA/EIA 568B Crossover
RJ-45
(8-Position)
RJ-45
(8-Position)
8
8
Br
Br
1
1
Gr/Wh
Gr/Wh
2
2
Gr
Gr
3
3
Wh/Or
Wh/Or
4
4
Bl
Bl
5
5
Wh/Bl
Wh/Bl
6
6
Or
Or
7
7
Wh/Br
Wh/Br
RJ-45
(8-Position)
RJ-45
(8-Position)
8
8
Br
Br
1
1
Wh/Or
Wh/Or
2
2
Or
Or
3
3
Wh/Gr
Wh/Gr
4
4
Bl
Bl
5
5
Wh/Bl
Wh/Bl
6
6
Gr
Gr
7
7
Wh/Br
Wh/Br
Note:
The BLU link network ring must be closed for the BLU link fault tolerance feature to
work. The fault tolerance feature ensures audio will still pass through the network if one of the
cables in the BLU link network is compromised. This means that when TR1616s are being used
as a digital snake, the TR1616s on both sides of the snake connection must complete the BLU
link ring. If using a single TR1616 on either side of the snake connection and no other BLU link
devices are connected, such as PMC16s, the LOOP OUT port should be connected to the LOOP IN
port to close the BLU link ring, as shown below. See page 12 to see full diagram.
BL
U link
LOOP OUT
to
IN
-->
SNAKE IN-->
<--SNAKE OUT
SNAKE OUT-->
<--SNAKE IN
Instrument
Instrument
Powered
Wedge Monitor
Powered
Wedge Monitor
Powered
Wedge Monitor
Instrument
Legend
Power Supply
Power Supply
Power Supply
BLU link Connection
BLU link Snake Connection
Analog Connection
Instruments
From Instruments
On Stage
Mixer
Outputs
<--BLU link LOOP IN
PMC16
PMC16
PMC16
TR1616
BL
U link fr
om
SNAKE OUT
(100 m/328 f
t max)
BL
U link t
o SNAKE IN
(100 m/328 f
t max)
BL
U link
LOOP OUT
to
LOOP
IN
-->
(closes the BL
U link r
ing
and allo
w
s the built
-in fault
toler
anc
e f
ea
tur
e t
o w
or
k)
Transmit Bank: 1
Receive Bank: 2
1
Transmit Bank: 2
Receive Bank: 1
2
STAGE
FRONT OF HOUSE
TR1616
01
02
02
01
BL
U link
OUT
to
L
OOP IN
-->
OUT
OUT
IN
IN
BLU link-->
BLU link-->
RX: 1 or 2
RX: 1 or 2
RX: 1 or 2
For more information on BLU link, please visit www.dbxpro.com.