1 description of the inverter, 1 connections – R&M Materials Handling VARIABLE SPEED CONTROLS CMXC 022 Service Manual User Manual
Page 3
R&M Materials Handling, Inc.
4501 Gateway Boulevard
Springfield, Ohio 45502
P.: (937) 328-5100
FAX: (937) 325-5319
3/14
R&M Materials Handling, Inc. reserves the right to alter or amend the above information without notice.
1 DESCRIPTION OF THE INVERTER
There are high voltages inside the inverter (including the programming switches).
Wait for at least three minutes after the supply voltage has been switched off before
any service actions.
1.Control terminal X1
2.Power terminal X2
3.Programming switches
4.Leds
3
2
1
4
1.1
Connections
Control signals are connected to terminal block X1 as follows:
Nbr
Name
Description
1
S1
Drive command. Direction 1. 48 or 115V 50/60Hz
2
S2
Drive command. Direction 2. 48 or 115V 50/60Hz
3
DI3
Digital input. 48 or 115V 50/60Hz.
4
DI4
Digital input. 48 or 115V 50/60Hz.
5
DI5
Digital input. 48 or 115V 50/60Hz.
6
ONE
Control voltage, neutral.
7
R01
Relay output
8
R02
Relay output
9
Empty
10
T1
Motor thermistor
11
T2
Motor thermistor
Power cabling is connected to terminal block X2 as follows:
Crane power supply conductor rail must have double collectors.
Nbr
Name
Description
1
L1
Mains, phase 1. 380-480V 50/60Hz.
2
L2
Mains, phase 2. 380-480V 50/60Hz.
3
L3
Mains, phase 3. 380-480V 50/60Hz.
4
U
Motor, phase 1.
5
V
Motor, phase 2.
6
W
Motor, phase 3.
7
R+
Braking resistor, positive, see note
8
R-
Braking resistor, negative, see note
9
PE
Protective earth