beautypg.com

1 description of the inverter, 1 connections – R&M Materials Handling VARIABLE SPEED CONTROLS CMXC 022 Service Manual User Manual

Page 3

background image

R&M Materials Handling, Inc.

4501 Gateway Boulevard

Springfield, Ohio 45502

P.: (937) 328-5100

FAX: (937) 325-5319

3/14

R&M Materials Handling, Inc. reserves the right to alter or amend the above information without notice.

1 DESCRIPTION OF THE INVERTER

There are high voltages inside the inverter (including the programming switches).
Wait for at least three minutes after the supply voltage has been switched off before
any service actions.

1.Control terminal X1

2.Power terminal X2

3.Programming switches

4.Leds

3

2

1

4

1.1

Connections

Control signals are connected to terminal block X1 as follows:

Nbr

Name

Description

1

S1

Drive command. Direction 1. 48 or 115V 50/60Hz

2

S2

Drive command. Direction 2. 48 or 115V 50/60Hz

3

DI3

Digital input. 48 or 115V 50/60Hz.

4

DI4

Digital input. 48 or 115V 50/60Hz.

5

DI5

Digital input. 48 or 115V 50/60Hz.

6

ONE

Control voltage, neutral.

7

R01

Relay output

8

R02

Relay output

9

Empty

10

T1

Motor thermistor

11

T2

Motor thermistor

Power cabling is connected to terminal block X2 as follows:

Crane power supply conductor rail must have double collectors.

Nbr

Name

Description

1

L1

Mains, phase 1. 380-480V 50/60Hz.

2

L2

Mains, phase 2. 380-480V 50/60Hz.

3

L3

Mains, phase 3. 380-480V 50/60Hz.

4

U

Motor, phase 1.

5

V

Motor, phase 2.

6

W

Motor, phase 3.

7

R+

Braking resistor, positive, see note

8

R-

Braking resistor, negative, see note

9

PE

Protective earth