MT-3109 AC/DC Digital Clamp Multimeter
F. Frequency
Range Resolution Accuracy
Overload
protection
10Hz 0.00Hz
100Hz 0.01Hz
1kHz 0.1Hz
10kHz 1Hz
100kHz 10Hz
1MHz 100Hz
+(0.1 %+5)
10MHz 1kHz reference
only
600Vp
Remark:
Input Sensitivity as follows:
When ≤ 100kHz: ≥ 300mV rms;
When > 100kHz: ≥ 600mV rms
When > 1MHz: ≥ 800mV rms
G. Duty Cycle
Range Resolution Accuracy
Overload
protection
0.1 %
~99.9%
0.1 %
reference
only
600Vp
H. DC Current
Range Resolution Accuracy Overload
protection
40.00A 0.01A +(2.5%+5)
400.0A 0.1A +(2.5%+3)
400A DC/AC
Warning
The operating temperature must be 0 ~40 when measuring
℃
℃
current.
Remark:
If the reading is positive, the current direction is from bottom to
up. See figure 10, the front case face up while the bottom case
face down. Hold the Meter tight, do now release. The hall
components are very sensitive not only to the magnet but also
to heat and machines reaction force. Any shock will cause
the changing in reading in the short time. Follow the below
procedure to measure current will be more precise: