fast-blown fuse
Frequency response: (40~200)Hz
Display: average value response (RMS of sine wave)

2-3-5.(Ω)

Range Accuracy

Resolution

200Ω ±(0.8%+5d)

0.1Ω

2kΩ

1Ω

20kΩ 10Ω
200kΩ 100Ω
2MΩ

±(0.8%+3d)

1kΩ

20MΩ ±(1.0%+25d)

10kΩ

200MΩ ±(5.0%+30d)

100kΩ

Open circuit voltage: less than 0.7V
Overload protection: 250V DC and AC peak value.
Note: At Range 200Ω, short-circuit the test lead to test the wire
resistance, and then subtract it from the real measurement.

WARNING: DO NOT input any voltage at resistance

range for safety!

2-3-6.(C)

Range Accuracy

Resolution

2nF ±(2.5%+20d)

1pF

20nF ±(2.5%+20d)

10pF

200nF ±(2.5%+20d)

100pF

2uF ±(2.5%+20d)

1nF

20uF ±(5.0%+10d)

10nF

• Overload protection: 36V DC or AC peak value

WARNING: DO NOT input any voltage at this range for

safety!