beautypg.com

Prokit's Industries MT-1270 User Manual

Page 3

background image

Property
1
General Properly
1-1. Display: LCD
1-2. Max display: 1999 (3 1/2 digit) automatic polarity display.
1-3. Measuring method: dual-integral A/D converter
1-4. Sampling Rage: approx. 3 times / sec.
1-5. Overrange display: LCD displays “1” or “-1”
1-6. Low battery display: “

”symbol appearance

1-7. Operation environment: (0~40)℃,Relative humidity: <80%
1-8. Power: a 9V battery (NEDA1604/6F22 or equivalent)
1-9. Dimension: 182 x 90 x 46 mm
1-10. Weight: approx. 320g (Not including 9V battery)
1-11. Accessory: user manual, CAT III test leads, temperature

probe, test socket


Technical Property
2-1.Accuracy: ±(a% x reading + digits) at (23±5)℃, relative

humidity <75%, one year calibration guarantee since the time
dispatched form the manufactory.

2-2.Functions: DC and AC Voltage, DC and AC Current,

Resistance, Capacitance, Frequency, Diode, Transistor,
Continuity, Temperature, Backlight, Auto power off, Overload
protection, Low battery indication

2-3-1.(DCV)

Range Accuracy

Resolution

200mV 100uV
2V 1mV
20V 10mV
200V

±(0.5%+3d)

100mV

1000V ±(0.8%+10d)

1V

Input Impedance: 10 MΩ at all the ranges.
Overload protection: 250V DC or AC peak value at Range
200mV, 1000V DC or AC peak value at other Ranges.

2