Warning – Peerless-AV DMU50SM - Installation User Manual
Page 3
Visit the Peerless Web Site at www.peerlessmounts.com
ISSUED: 03-26-09 SHEET #: 125-9060-5 07-26-13
Installation to Wood Stud Walls
Use a stud finder to locate the edges of the stud.
Use of an edge-to-edge stud finder is highly
recommended. Based on its edges, draw a vertical
line down the stud’s center. Place wall plate (
A)
on wall as a template. Mark the center of the four
mounting holes. Drill four 5/32” (4 mm) dia. holes
2-1/2” (65 mm) deep. Secure wall plate (
A) to wood
stud using four #14 x 2-1/2” wood screws (
I) as
shown.
• Installer must verify that the supporting surface will safely support the combined load of the equipment and all
attached hardware and components.
• Tighten wood screws so that wall plate is firmly attached, but do not overtighten. Overtightening can damage the
screws, greatly reducing their holding power.
• Never tighten in excess of 80 in. • lb (9 N.M.).
• Make sure that mounting screws are anchored into the center of the stud. The use of an “edge to edge” stud finder
is highly recommended.
• Hardware provided is for attachment of mount through standard thickness drywall or plaster into wood studs.
Installers are responsible to provide hardware for other types of mounting situations.
WARNING
1
A
2
Secure four .219 ID x .5 X OD x .25 tall nylon spacer
(
L) and four M5 x 10 mm socket pin serrated washer
head screw (
D) to bottom of wall plate (A). Secure
one M5 x 16 mm socket pin serrated washer head
screw (
E) and one .219 ID x .5 X OD x .5 tall nylon
spacer (
H) to top of wall plate as shown below.
E
H
L
D
I
A
Skip to step 3 on page 5