Installation to Wood Stud Wall

• Installer must verify that the supporting surface will safely support the combined load of the equipment and all

attached hardware and components.

• Tighten wood screws so that wall plate is fi rmly attached, but do not overtighten. Overtightening can damage the

screws, greatly reducing their holding power.

• Never tighten in excess of 80 in. • lb (9 N.M.).

• Make sure that mounting screws are anchored into the center of the stud. The use of an "edge to edge" stud fi nder

is highly recommended.

• Hardware provided is for attachment of mount through standard thickness drywall or plaster into wood studs.

Installers are responsible to provide hardware for other types of mounting situations (not evaluated by UL).

WARNING

LEFT

ORIENTATION

RIGHT

ORIENTATION

fi g. 1.2

fi g. 1.3

C

A

fi g. 1.4

D

B

A

A

FLANGE

FLANGE

In-wall box (A) must be installed between two studs
16" on center. Use an edge-to-edge stud fi nder to
locate the edges of the stud. Based on its edges,
draw two vertical lines down the inside edges of
stud’s. Mark desired center of in-wall box. Draw a
horizontal line 6-1/8" (155 mm) above center of
in-wall box (A). Draw a second horizontal line
12-1/4" (311 mm) below this line to outline wall
opening between inside edges of studs. Remove
drywall inside cut outline. NOTE: In-wall box (A) can
be installed for left or right side mount orientation as
shown in fi gure 1.2.

Insert in-wall box (A) into cut-out until fl ange is
fl ush with drywall. Level in-wall box (A), and mark
the position of two mounting holes using holes on
mounting tabs. Remove in-wall box (A) and drill
1/8" (3 mm) dia. holes 1-1/2" (38 mm) deep using
the locations previously marked. Reinstall and
level in-wall box (A). Secure using two #10 x 1-1/2"
wood screws (B) as shown in fi gure 1.3. Attach two
mounting cover plates (C) to in-wall box (A) using
four ribbed rivets (D) as shown in fi gure 1.4.

1

fi g. 1.1

12-1/4"

(311mm)

14-1/2"

(368mm)

STUD

6-1/8"

(155mm)

CUT

OUTLINE

CENTER OF

IN-WALL BOX

MOUNTING

TABS