Warning, Bd a p n – Peerless-AV ESA746PU - Installation User Manual
Page 5
5 of 35
ISSUED: 01-15-11 SHEET #: 061-9061-3 11-19-13
B
D
A
P
N
3.95"
(100mm)
CS = Center of Screen
CS
fi g. 1.1
fi g. 1.2
fi g. 1.3
Installation to Wood Stud Wall
Use a stud fi nder to locate the edges of the studs and draw a vertical line down the center of each stud. Use wall
plate (B) as a template to mark center of four mounting holes. The top mounting slots should be located 3.95"
(100mm) above the desired screen center as shown in fi gure 1.1. Drill four 5/32" (4mm) dia. holes to a depth
of 2-1/2" (64mm). Attach wall plate (B) to wall using three wood screws (D) and one security wood screw (N) as
shown in fi g. 1.2. Level wall plate then tighten all fasteners.
Attach wall arm (A) to wall plate (B) with two 1/4-20 x 1/2" socket pin screws (P) as shown in fi gure 1.3.
• Installer must verify that the supporting surface will safely support the combined load of the equipment and all
attached hardware and components.
• Tighten wood screws so that wall plate is fi rmly attached, but do not overtighten. Overtightening can damage the
screws, greatly reducing their holding power.
• Never tighten in excess of 80 in. • lb (9 N.M.).
• Make sure that mounting screws are anchored into the center of the stud. The use of an "edge to edge" stud fi nder
is highly recommended.
• Hardware provided is for attachment of mount through standard thickness drywall or plaster into wood studs.
Installers are responsible to provide hardware for other types of mounting situations (not evaluated by UL).
WARNING
1
STUD