beautypg.com

Warning, E, j, or k, Figure 2.2 figure 2.3 – Peerless-AV SUA746H - Installation User Manual

Page 6

background image

6 of 7

ISSUED: 05-01-12 SHEET #: 125-9307-1

• Tighten screws so display brackets are firmly attached to display. Do not tighten with excessive force.

Overtightening can cause stress damage to screws, greatly reducing their holding power and possibly causing

screw heads to become detached. Tighten to 40 in. • lb (4.5 N.M.) maximum torque.

• If screws don't get three complete turns in the display inserts or if screws bottom out and bracket is still not tightly

secured, damage may occur to display or product may fail.

WARNING

Installing Adapter Brackets to Display

2

FIGURE 2.1

DISPLAy

ADAPTeR

PLATe

keyHOLe SLOT

ADAPTER PLATE MOUNTING DETAIL

1/8"

DISPLAy

Use adapter plate detail figure 2.1 to determine

display hole pattern.
To prevent scratching the display, set a cloth on a

flat, level surface that will support the weight of the

display. Place display face side down. Fasten two M8

x 10 mm socket pin screws (

J) or M8 x 15 mm socket

pin screws (

K) or M6 x 12 mm socket pin screws (E)

into top mounting holes in back of display as shown in

figure 2.2

Hook exposed screws into keyhole slots on adapter

plate on wall arm assembly (A) and secure using two

M8 x 10 mm socket pin screws (

J) or M8 x 15 mm

socket pin screws (

K) or M6 x 12 mm socket pin

screws (

E) into bottom mounting holes

as shown in figure 2.3.

FIGURE 2.2

FIGURE 2.3

E, J, or K

E, J, or K

15.75"

(400 mm)

15.75"

(400 mm)

11.81"

(300 mm)

11.81"

(300 mm)

7.87"

(200 mm)

7.87"

(200 mm)