5 of 7

ISSUED: 05-01-12 SHEET #: 125-9307-1

Place wall arm (

A) on wall as template, level,

and mark the center of two mounting holes. Top

mounting hole will be 6.66" above the center of

display mounting plate as shown in figure 1.1 on

page 4. Drill two 5/16" dia. holes to a minimum

depth of 2.5". Insert anchors (

D) into holes flush

with wall as shown. Secure wall arm (

A) to wall with

two wood screws (

C) as shown in figure 1.3. For

cable management option, install cable anchor (

I) to

bottom mounting hole with wood screw (

C).

NOTE: Be sure arrow is pointing up when mounting

wall arm assembly (

A) to wall as shown in figure

1.1. on page 4. Level, then tighten all fasteners.
Insert two fastener caps (

H) into wall plate mounting

holes.

D

SOLID CONCReTe

CINDeR BLOCk

1

Installation to Solid Concrete or Cinder Block

CUT

AW

AY

VIEW

INCORRECT

CORRECT

wall

plate

wall

plate

plaster/

dry wall

plaster/

dry wall

concrete

concrete

• When installing Peerless wall mounts on cinder block, verify that you have a minimum of 1-3/8" (35 mm) of actual

concrete thickness in the hole to be used for the concrete anchors. Do not drill into mortar joints! Be sure to mount

in a solid part of the block, generally 1" (25 mm) minimum from the side of the block. Cinder block must meet ASTM

C-90 specifications. It is suggested that a standard electric drill on slow setting is used to drill the hole instead of a

hammer drill to avoid breaking out the back of the hole when entering a void or cavity.

• Concrete must be 2000 psi density minimum. Lighter density concrete may not hold concrete anchor.
• Make sure that the supporting surface will safely support the combined load of the equipment and all attached

hardware and components.

WARNING

• Tighten screws so that wall plate is firmly attached,

but do not overtighten. Overtightening can damage

screws, greatly reducing their holding power.

• Never tighten in excess of 80 in. • lb (9 N.M.).
• Always attach concrete expansion anchors directly

to load-bearing concrete.

• Never attach concrete expansion anchors to

concrete covered with plaster, drywall, or other

finishing material. If mounting to concrete surfaces

covered with a finishing surface is unavoidable,

the finishing surface must be counterbored as

shown below. Be sure concrete anchors do not

pull away from concrete when tightening screws. If

plaster/drywall is thicker than 5/8" (16 mm), custom

fasteners must be supplied by installer.

WARNING

A

C

H

I

1

3

D

Drill holes and insert anchors (

D).

Place plate (

A) over anchors (D) and secure with screws (C).

Tighten all fasteners.

2

D

A

C

concrete

surface

FIGURE 1.3