ISSUED: 03-23-09 SHEET #:055-9260-8 04-25-13

5 of 9

Note: For PSTK-028 models, refer to page 6.

Drill four 5/16" (8 mm) dia. holes to a minimum
depth of 2.5" (64 mm). Insert anchors (G) in
holes fl ush with wall as shown. Attach wall arm
(A) using four #14 x 2 -1/2" wood screws (E) as
shown in Illustration A and 1, 2, and 3. Tighten
all fasteners. Optional: Rotate wall arm 180° to
position the arm closer to the ceiling.

Skip to Step 2.

1

E

G

Illustration A

A

Installation to Solid Concrete or Cinder Block Wall

for PSTA-028, PSTA-028-W Models

• Tighten wood screws fi rmly, but do not overtighten.

Overtightening can damage the screws, greatly
reducing their holding power.

• Never tighten in excess of 80 in • lb (9 N.M.).

WARNING

• Concrete anchors are not intended for attachment to

concrete wall covered with a layer of plaster, drywall,
or other fi nishing material. If mounting to concrete
wall covered with plaster/drywall is unavoidable (not
evaluated by UL), plaster/drywall (up to 5/8" thick)
must be counterbored as shown right. If plaster/
drywall is thicker than 5/8", custom fasteners must
be supplied by installer (not evaluated by UL).

WARNING

CUT

A

W

A

Y

VIEW

INCORRECT

CORRECT

wall

plate

wall

plate

plaster/
dry wall

plaster/
dry wall

concrete

concrete

WARNING

• When installing Peerless wall mounts on cinder block, verify that you have a minimum of 1-3/8" of actual concrete

surface in the hole to be used for the concrete anchors. Do not drill into mortar joints! Be sure to mount in a
solid part of the block, generally 1" minimum from the side of the block. Cinder block must meet ASTM C-90
specifi cations. It is suggested that a standard electric drill on slow setting is used to drill the hole instead of a
hammer drill to avoid breaking out the back of the hole when entering a void or cavity.

• Concrete must be 2000 psi density minimum. Lighter density concrete may not hold concrete anchor.

• Make sure that the wall will safely support four times the combined load of the equipment and all attached hardware

and components.

1

3

G

Drill holes and insert anchors (G).

Place plate (A) over anchors (G) and secure with screws (E).

Tighten all fasteners.

2

G

A

E

concrete
surface