beautypg.com

Warning – Peerless-AV EPMU-08-S - Installation User Manual

Page 4

background image

4 of 32

ISSUED: 06-22-10 SHEET #: 061-9053-6 01-15-11

Use support column (A) as a template to mark eight mounting holes on concrete fl oor. Drill eight 3/8" (10 mm) dia.
pilot holes to a minimum depth of 3" (76 mm) as shown. Place support column over mounting holes and secure
with eight concrete expansion anchors (B) as shown below. Tighten all fasteners.

1

Installation to Solid Concrete surface

A

B

Tighten all fasteners. Tighten to 35 ft. • lb (47 N.M.) maximum
torque.

A

B

concrete
fl oor

• Installer must verify that the supporting surface will safely support the combined load of the equipment and all

attached hardware and components.

• For attachment to concrete fl oor only. All eight concrete expansion anchors must be used.

• Tighten to 35 ft. • lb (47 N.M.) maximum torque.

WARNING