Mounting and Removing Display
• Always use an assistant or mechanical lifting equipment
to safely lift and position the flat panel display.
• Do not tighten screws with excessive force.
Overtightening can cause damage to mount. Tighten
screws to 40 in. • lb (4.5 N.M.) maximum torque.
• Be careful not to pinch fingers when pushing display from
the bottom.
WARNING
© 2012, Peerless Industries, Inc. All rights reserved.
All other brand and product names are trademarks or registered trademarks of their respective owners.
Peerless Industries, Inc.
2300 white oak Circle
Aurora, Il 60502
www.peerless-av.com
Hook right and left hook brackets (
B and C) onto
pems on wall plate (
A) as shown in Figure 3.1
Detail 2.
Secure right and left hook brackets (
B and C) to
wall plate (
A) with two M5 x 10 mm socket pin
Type-F screws (M) using 4 mm allen wrench (
e)
as shown in Detail 3
3
FIGURe 3.1
Attaching Hook Brackets to Back of Display
Attach right and left hook brackets (
B and C) to back
of display using four M6 x 12 mm socket pin serrated
washer head screws (
D) with nylon shoulder washers
(
H) or, M8 x 10 mm socket pin screws (F), or M8 x 15
mm socket pin screws (
G).
2
H
D, F or G
TOP OF
DISPLAY
B
C
B and C
A
A
M
PEM
DeTAIL 1 B
FLANGe
DeTAIL 2
C
DeTAIL 3
DISPLAY
D
B or C
H
FLANGe
NoTe: If screws don't get three complete turns
in the display inserts or if screws bottom out
and bracket is still not tightly secured, damage
may occur to display or product may fail.
NoTe: Bracket orientation as shown in Detail 1 A, Detail 1 B
NoTe: Nylon shoulder washers (H) are only used with
M6 x 12 mm socket pin serrated washer head screws (
D).
DeTAIL 1 A