ISSUED: 04-10-12 SHEET #: 125-9295-2 04-26-12
Installation to Double Wood Stud Wall
Use a stud finder to locate the edges of the studs. Use of an edge-to-edge stud finder is highly recommended.
Based on their edges, draw a vertical line down each stud’s center. Place wall plate on wall as a template.
Level plate, and mark the center of the four mounting holes. Make sure that the mounting holes are on the stud
centerlines. Drill four 5/32" (4mm) dia. holes 2.5" (64mm) deep. Make sure that the wall plate is level, secure it
using four #14 x 2.5" wood screws (
DD) as shown in figure 1.2.
Skip to step 2.
• Installer must verify that the supporting surface will safely support the combined load of the equipment and all
attached hardware and components.
• Tighten wood screws so that wall plate is firmly attached, but do not overtighten. Overtightening can damage the
screws, greatly reducing their holding power.
• Never tighten in excess of 80 in. • lb (9 N.M.).
• Make sure that mounting screws are anchored into the center of the stud. The use of an "edge to edge" stud finder
is highly recommended.
• Hardware provided is for attachment of mount through standard thickness drywall or plaster into wood studs. Install-
ers are responsible to provide hardware for other types of mounting situations.
WARNING
1
FIGURe 1.1
A
I
wooD STUD
NoTe: DIAMOND INDICATeS
TOP OF WALL PLATe