beautypg.com

Installation to single wood stud wall, Ao b h, Warning – Peerless-AV ESHV30 - Installation User Manual

Page 4: Fi g. 1.2

background image

4 of 27

ISSUED: 01-21-11 SHEET #: 083-9014-1

1

fi g. 1.1

fi g. 1.2

Remove end cap with bubble level from column (A). Assemble columns (A) and clip (O)
as shown in fi gure 1.1. The columns can be mounted to a single stud. Use a stud fi nder to
locate the edges of the stud. Use of an edge-to-edge stud fi nder is highly recommended.
Based on their edges, draw a vertical line down the stud’s center. Place columns (A) on wall
as a template. Level column and mark the center of the mounting holes as shown in fi gure
1.1. Make sure that the center mounting holes are on the stud center lines. Drill four mounting
holes .12" (3mm) dia. by 2" (51mm) deep. Secure column (A) with four M5 X 44mm wood
screws (B) as shown in fi gure 1.2.

Tighten fasteners then cover M5 X 44mm wood screws (B) with screw covers (H).

Skip to step 2

Installation to Single Wood Stud Wall

STUD

DRILL .12" DIA

HOLES

END CAP

A

O

B

H

• Installer must verify that the supporting surface will safely support the combined load of the

equipment and all attached hardware and components.

• Tighten wood screws so that wall plate is fi rmly attached, but do not overtighten. Overtightening

can damage the screws, greatly reducing their holding power.

• Never tighten in excess of 80 in. • lb (9 N.M.).

• Make sure that mounting screws are anchored into the center of the stud. The use of an "edge to

edge" stud fi nder is highly recommended.

• Hardware provided is for attachment of mount through standard thickness drywall or plaster into

wood studs. Installers are responsible to provide hardware for other types of mounting situations.

WARNING