High performance wireless ethernet bridge, Ghostbridge – B&B Electronics GHOSTBRIDGE5 - Datasheet User Manual
Page 2
International Office: 707 Dayton Road PO Box 1040 Ottawa, IL 61350 USA 815-433-5100 Fax 433-5104
European Office: Westlink Commercial Park Oranmore Co. Galway Ireland +353 91 792444 Fax +353 91 792445
High Performance Wireless
Ethernet Bridge
GHOSTBRIDGE
sPEcificatiOns
etherNet iNterface
Ethernet Port 1
RJ45
Ethernet Port 2
RJ45
LED’s
Power, LAN1, LAN2, 4 wireless signal strength
power
PoE Power
24V PoE powered device through Ethernet port + pins
4,5, - pins 7, 8
Included PoE Injectors
(2) 100-240VAC input @ 50-60 Hz 24V out, 0.5A out
PoE injectors
(2) DC input PoE injector with 1m power jack to
stripped wires
Power
8 Watts maximum power consumption
rf
Operating Frequency
5470 – 5825 GhostBridge5
TX Power (Avg)
21 – 27 dBm +/- 2dB (varies by mode/conditions)
RX Sensitivity
-74 – 96 dBm +/- 2dB (varies by mode/conditions)
Antenna Type
Integrated 2x2 MIMO. 80 degree sector
Antenna gain
14.6 – 16.1 dBi over 4.9 – 5.9 GHz
Security
Each pair is preconfigured to WPA2 128 bit
MechaNical
Dimensions
11 x 3.2 x 1.2 in (28 x8 x 3 cm) body
11 x 3.2 x 2.4 in (28 x8 x 6 cm) including built-in
brackets
Weight per unit
0.86 lbs (0.4 kg)
Shipping weight
3.0 lbs (1.4 kg)
Mounting
Integrated pole mount, wire ties included
Optional wall/pole mount swivel bracket sold
separately
Enclosure
IP54. UV Stabilized plastic.
eNviroNMeNtal
Operating Temperature
-30 to 80°C (-40 to 176°F)
Storage Temp
-40 to 85°C (-40 to 185°F)
Operating Humidity
0 to 95 % (Non-condensing)
approvals / certificatioNs
Emissions
FCC Class B, CISPR Class B (EN55022)
CE
EN61000-6-1:2007
EN61000-4-2:2008 Electrostatic Discharge
EN61000-4-3:2006 Radiated Immunity
EN61000-4-4:2004 Electrical Fast Transients - Burst
EN61000-4-6:2005 Conducted Immunity
EN61000-4-11:2004 Voltage Dips and Interruptions
EN 301 489-1 V1.4.1: 2002-08 Electromagnetic
Compatibility
EN 301 489-17 V1.2.1: 2002-08 Electromagnetic
Compatibility
EN 301 893-1 V1.4.1: 2007 Directive for 5 GHz Radio
Equipment
EN 50385: 002 RF Exposure Limits
EN 60950-1: 2006 Safety for Information Technology
Equipment