B&B Electronics ADAM-5000_TCP - Datasheet User Manual
Features, Introduction, Specifications

Features
Programmable Automation Controllers & Software
Introduction
ADAM-5000L/TCP and ADAM-5000/TPC are both Ethernet-based I/O systems. Without a repeater, ADAM-5000L/TCP and ADAM-5000/TCP can cover a communication distance up
to 100 m. This allows remote configuration via Ethernet and eight PCs can simultaneously access the data. The ADAM-5000L/TCP and ADAM-5000/TCP are the solutions for easy
configuration and efficient management. An ideal and cost-effective solution for eAutomation architecture.
ADAM-5000L/TCP
ADAM-5000/TCP
ARM 32-bit RISC CPU
10/100Base-T auto-negotiation high-speed communication port
Supports Modbus/TCP for easy integration
Supports UDP event handling function
Up to 100 m communication distance w/o repeater
Allows remote configuration via Ethernet
Allows concurrent access for 8 host PCs
4 I/O slots for up to 64 points and 8 I/O slots for up to 128 points data
monitoring and control
1500 V
DC
isolation for Ethernet communication
Built-in watchdog timer for system auto-reset
Windows utility
- I/O modules configuration and calibration
- Network auto searching
- Data stream setting
- Current status monitoring and alarm trigger
Provides .NET Class LIB to develop applications
Specifications
Control System
CPU
32-bit ARM RISC
I/O Slots
ADAM-5000L/TCP: 4
ADAM-5000/TCP: 8
Memory
Flash ROM: 512 KB
RAM: 4 MB
Operating System
Real-time OS
LED Indicators
Power (3.3 V, 5 V)
CPU
Communication (Link, Active, 10/100 Mbps, Tx, Rx)
Battery
Communications (Ethernet)
Comm. Distance
100 meters w/o repeater
Comm. Protocol
Modbus/TCP, TCP, UDP, IP, ARP
Data Transfer Rate
Up to 100 Mbps
Event Response Time < 5 ms
Interface
1 x 10/100Base-T (RJ-45)
Wiring
UTP, category 5 or greater
Communications (Serial)
Comm. Distance
RS-485: 1.2 km (4000 feet)
RS-232: 15 m
Comm. Protocol
Modbus/RTU
Data Transfer Rate
Up to 115.2 kbps
Interface
1 x DB9-M for RS-485
1 x DB9-F for RS-485
1 x DB9-F for RS-232
Max. Nodes
12 (in RS-485 daisy-chain network for Remote I/O
connection)
Power
Power Consumption
4.0 W @ 24 Vdc (ADAM-5000L/TCP)
(not including I/O modules)
5.0 W @ 24 Vdc (ADAM-5000/TCP)
(not including I/O modules)
Power Input
Unregulated 10 ~ 30 V
DC
Software
.NET Class LIB
Windows Utility
Network setting, I/O configuration & calibration, data
stream, alarm setting
Modbus/TCP OPC Server
Protection
Communication Line
3000 V
DC
Isolation
I/O Module Isolation
3000 V
DC
LAN Communication
1500 V
DC
Overvoltage Protection Yes
Power Reversal
Yes
Protection
General
Certifications
CE, FCC class A
Connectors
1 x DB9-M/DB9-F/screw terminal for RS-485
(communication)
1 x DB9-F for RS-232 (internal use)
1 x Screw-terminal for power input
1 x RJ-45 for LAN
Dimensions (W x H x D) ADAM-5000L/TPC: 231 x 110 x 75 mm
ADAM-5000/TCP: 355 x 110 x 75 mm
Enclosure
ABS+PC
Mounting
DIN 35 rail, wall
Environment
Humidity
5 ~ 95%, non-condensing
Operating Temperature - 10 ~ 70° C (14 ~ 158° F)
Storage Temperature - 25 ~ 85° C (-13 ~ 185° F)
Ordering Information
ADAM-5000L/TCP
4-slot Ethernet-based Distributed DA&C System
ADAM-5000/TCP
8-slot Ethernet-based Distributed DA&C System
4-slot Ethernet-based Distributed
DA&C System
8-slot Ethernet-based Distributed
DA&C System
ADAM-5000/TCP
ADAM-5000L/TCP