B&B Electronics SD-15 Series - Datasheet User Manual
S d - 1 5, 15w single output dc-dc converter, Specification

DC VOLTAGE
SPECIFICATION
MODEL
OUTPUT
RATED CURRENT
CURRENT RANGE
RATED POWER
RIPPLE & NOISE (max.)
Note.2
VOLTAGE TOLERANCE
Note.3
LINE REGULATION
LOAD REGULATION
VOLTAGE RANGE
SETUP, RISE ,HOLD UP TIME
EFFICIENCY(Typ.)
DC CURRENT(Typ.)
OVER LOAD
OVER VOLTAGE
WORKING TEMP.
WORKING HUMIDITY
STORAGE TEMP., HUMIDITY
TEMP. COEFFICIENT
VIBRATION
WITHSTAND VOLTAGE
ISOLATION RESISTANCE
DIMENSION
INPUT
PROTECTION
ENVIRONMENT
SAFETY &
EMC
(Note 4)
OTHERS
NOTE
12V
1.25A
0 ~ 1.25A
15W
120mVp-p
1.0%
0.3%
0.3%
1.0%
0.2%
0.2%
2.5s, 25ms,--- 12VDC/24VDC/48VDC at full load
A: 9.2 ~18VDC
B
C:36~72VDC
:18 ~ 36VDC
68%
1.9A/12VDC
0.9A/24VDC
0.45A/48VDC
105 ~160%
rated output power
Protection type : Hiccup mode, recovers automatically after fault condition is removed
5.75 ~ 6.75V
¡
20 ~ 90% RH non-condensing
10 ~ 500Hz, 2G 10min./1cycle, 60min.each along X, Y, Z axes
I/P-O/P:2KVAC I/P-FG:1KVAC
O/P-FG:0.5KVAC
I/P-O/P,I/P-FG,O/P-FG:100M Ohms / 500VDC / 25
/ 70% RH
78*51*28mm (L*W*H)
SD-15C-12
5V
3A
0 ~ 3A
15W
100mVp-p
2.0%
0.5%
0.5%
24V
0.625A
0 ~ 0.625A
15W
150mVp-p
72%
70%
13.8~ 16.2V
27.6 ~ 32.4V
EMI CONDUCTION&RADIATION Compliance to EN55022(CISPR22) CLASS B
SD-15A-24
SD-15A-12
SD-15B-12
SD-15B-24
SD-15C-24
SD-15C-05
SD-15B-05
SD-15A-05
76%
75%
76%
79%
77%
78%
VOLTAGE ADJ.RANGE
4.75~5.5VDC
10.8~13.2VDC
21.6~26.4VDC
EMS IMMUNITY
Compliance to EN61000-4-2,3,4,6,8;ENV50204,EN55024,light industry level,criteria A
PACKING
0.18kg,60 PCS/11.8kg
Protection type : Shut down o/p voltage, re-power on to recover
-10 ~ +60
(Refer to output load derating curve)
-20 ~ +85
, 10 ~ 95% RH
15W Single Output DC-DC Converter
S D - 1 5
s e r i e s
2:1 wide input range
Protections:Short circuit/Over load /voltage
Built-in EMI filter, low ripple noise
100% full load burn-in test
Low cost
High reliability
2 years warranty
Features :
File Name:SD-15-SPEC 2010-10-18
1. All parameters NOT specially mentioned are measured at normal input, rated load and 25
of ambient temperature.
2. Ripple & noise are measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor.
3. Tolerance : includes set up tolerance, line regulation and load regulation.
4. The power supply is considered a component which will be installed into a final equipment. The final equipment must be re-confirmed that it still meets
EMC directives. For guidance on how to perform these EMC tests, please refer to EMI testing of component power supplies.
(as available on http://www.meanwell.com)
0.03%/
(0 ~ 50
)