beautypg.com

B&B Electronics MDR-60 Series - Datasheet User Manual

M d r - 6 0, 60w single output industrial din rail power supply, Specification

background image

SPECIFICATION

MDR-60-5

MDR-60-12

MDR-60-24

MDR-60-48

MODEL

DC VOLTAGE

RATED CURRENT

CURRENT RANGE

RATED POWER

OUTPUT

VOLTAGE ADJ. RANGE

LINE REGULATION

LOAD REGULATION

SETUP, RISE TIME

Note.5

HOLD UP TIME (Typ.)

VOLTAGE RANGE

FREQUENCY RANGE

EFFICIENCY (Typ.)

AC CURRENT (Typ.)

INPUT

INRUSH CURRENT (Typ.)

SAFETY STANDARDS

HARMONIC CURRENT

EMS IMMUNITY

WORKING HUMIDITY

WORKING TEMP.

STORAGE TEMP., HUMIDITY

TEMP. COEFFICIENT

VIBRATION

MTBF

DIMENSION

OTHERS

NOTE

PACKING

OVERLOAD

OVER VOLTAGE

5V

12V

24V

48V

10A

5A

2.5A

1.25A

0 ~ 10A

0 ~ 5A

0 ~ 2.5A

0 ~ 1.25A

50W

60W

60W

60W

80mVp-p

120mVp-p

150mVp-p

24 ~ 30V

200mVp-p

48 ~ 56V

2.0%

1.0%

1.0%

1.0%

12 ~ 15V

5 ~ 6V

1.0%

1.0%

1.0%

1.0%

1.5%

1.0%

1.0%

1.0%

500ms, 30ms/230VAC

500ms, 30ms/115VAC at full load

50ms/230VAC

20ms/115VAC at full load

85 ~ 264VAC

120 ~ 370VDC

47 ~ 63Hz

78%

86%

88%

87%

1.8A/115VAC

1A/230VAC

COLD START 30A/115VAC

60A/230VAC

105 ~ 150% rated output power

Protection type : Constant current limiting, recovers automatically after fault condition is removed

6.25 ~ 7.25V

Protection type : Shut down o/p voltage, re-power on to recover

15.6 ~ 18V

31.2 ~ 36V

57.6 ~ 64.8V

-20 ~ +70

(Refer to output load derating curve)

20 ~ 90% RH non-condensing

-40 ~ +85

, 10 ~ 95% RH

0.03%/

(0 ~ 50

Component :

each along X, Y, Z axes ; Mounting : Compliance to IEC60068-2-6

10 ~ 500Hz, 2G 10min./1cycle, period for 60min.

299.2K hrs min.

MIL-HDBK-217F (25

)

1. All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25

of ambient temperature.

2. Ripple & noise are measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor.
3. Tolerance : includes set up tolerance, line regulation and load regulation.
4. The power supply is considered a component which will be installed into a final equipment. The final equipment must be re-confirmed that it still meets

EMC directives.

5. Length of set up time is measured at first cold start. Turning ON/OFF the power supply may lead to increase of the set up time.

File Name:MDR-60-SPEC 2007-07-09

UL508, TUV EN60950-1 approved, NEC class 2 / LPS compliant (24V,48V only)

Compliance to EN61000-3-2,-3

60W Single Output Industrial DIN Rail Power Supply

M D R - 6 0

s e r i e s

RIPPLE & NOISE (max.)

Note.2

VOLTAGE TOLERANCE

Note.3

ENVIRONMENT

PROTECTION

SAFETY &

EMC

(Note 4)

WITHSTAND VOLTAGE

ISOLATION RESISTANCE

EMI CONDUCTION & RADIATION

Universal AC input/Full range

Protections: Short circuit / Overload / Over voltage

Cooling by free air convection

Can be installed on DIN rail TS-35/7.5 or 15

NEC class 2 / LPS compliant (24V,48V only)

LED indicator for power on

DC OK relay contact

No load power consumption<0.75W

100% full load burn-in test

3 years warranty

Features :

40*90*100mm (W*H*D)

0.33Kg; 42pcs/14.8Kg/0.82CUFT

LEAKAGE CURRENT

<1mA / 240VAC

I/P-O/P:3KVAC

I/P-FG:1.5KVAC

O/P-FG:0.5KVAC

I/P-O/P, I/P-FG, O/P-FG:>100M Ohms/500VDC 25

70%RH

FUNCTION DC OK SIGNAL

Relay contact rating(max.): 30V/1A resistive

Compliance to EN55011, EN55022 (CISPR22), EN61204-3 Class B

Compliance to EN61000-4-2, 3, 4, 5, 6, 8, 11, ENV50204, EN55024, EN61000-6-2, EN61204-3, heavy industry level, criteria A