beautypg.com

Standard serial/fiber optic converters, Fostcdr, fostcdrkt, fostcdr-inv – B&B Electronics FOSTCDRKT - Datasheet User Manual

Page 2

background image

International Office: 707 Dayton Road PO Box 1040 Ottawa, IL 61350 USA 815-433-5100 Fax 433-5104

European Office: Westlink Commercial Park Oranmore Co. Galway Ireland +353 91 792444 Fax +353 91 792445

[email protected]

[email protected]

Standard Serial/Fiber

optic Converters

FOSTCDR, FOSTCDRKT, FOSTCDR-INV

SpeCiFiCationS

serial teChnology

Data Rate

RS-232: 115.2 Kbps maximum

RS-422/485: 460.8 Kbps maximum

rs-232

Connector Terminal block (24 to 14 AWG)

RS-232 TD, RD, GND

rs-422/485

Connector Terminal block (24 to 14 AWG)

RS-485, 2-wire

Data A(-), Data B(+), GND

RS-422/485, 4-wire

TDA(-), TDB(+), RDA(-), RDB(+), GND

isolation

Rating

2KV RMS, 1 minute

Lines Protected

2-way (input, output lines)

Method

Optical

Fiber oPtiC teChnology

Type / Wavelength

Multi-mode / 820 nm

Output Power

(-) 17 to (-) 10 dBm

Receive Sensitivity

(-) 25.4 dBm to (-) 24 dBm

Cable

62.5/125 micro-meter

Connector

ST

Data Rate

9.6 to 115.2 kbps

Maximum Distance

4 km (2.5 mi)

Idle State

Transmitter light ON

Power

Source

External

Input Voltage

10 to 30 VDC

Consumption

1.7 Watts

Connector

Terminal block, (24 to 14 AWG)

industrial bus

Modbus

ASCII/RTU

MeChaniCal

LED Indicators

Serial TD, RD, and Power

Dimensions

10.6 x 7.9 x 2.5 cm (4.3 x 2.3 x 0.95 in)

Enclosure

35mm DIN mount, plastic

Weight

182 g (0.4 lbs)

environMental

Operating Temperature

-40 to +80 °C (-40 to +176 °F)

Storage Temperature

-40 to +85 °C (-40 to +185 °F)

Operating Humidity

0 to 95% non-condensing

aPProvals / CertiFiCations - FostCdr

cULus Recognized, File Number: E222870
FCC Part 15, CISPR, EN 55022: 2010 + AC:2011 Class A Emissions
CE
EN 61000-6-1: 2007 Generic Standards for Residential, Commercial and Light-

Industrial Environments

EN 61000-4-2: 2009 Electro-Static Discharge (ESD)

EN 61000-4-3: 2006 +A1 +A2 +IS1 Radiated Field Immunity (RFI)

EN 61000-4-4: 2012 Electrical Fast Transients-Burst Immunity (EFT)

EN 61000-4-6: 2009 Conducted Immunity

Download complete Declaration of Conformity at www.bb.elec.com

aPProvals / CertiFiCations - FostCdr -inv

UL 508, File Number: E222870
FCC Part 15, CISPR, EN 55022: 2010 + AC:2011 Class A Emissions
CE

MtbF

FOSTCDR

460854 hours

FOSTCDR-INV

138904 hours

Calculation Method

MIL 217F Parts Count Reliability Prediction

Dimensional Diagram of FOSTCDR

meChaniCaL Diagram