Table 11. channel id tag codes, Switching network – Rainbow Electronics MAX1400 User Manual
Page 20

MAX1400
+5V, 18-Bit, Low-Power, Multichannel,
Oversampling (Sigma-Delta) ADC
20
______________________________________________________________________________________
Table 11. Channel ID Tag Codes
Switching Network
A switching network provides selection between three
fully differential input channels or five pseudo-differen-
tial channels, using AIN6 as a shared common. The
switching network provides two additional fully differen-
tial input channels intended for system calibration,
which may be used as extra fully differential signal
channels. Table 12 shows the channel configurations
available for both operating modes.
Scanning (SCAN-mode)
To sample and convert the available input channels
sequentially, set the SCAN control bit in the global
setup register. The sequence is determined by DIFF
(fully differential or pseudo-differential) and by the
mode control bits M1 and M0 (Tables 8, 9, 10). With
SCAN set, the part automatically sequences through
each available channel, transmitting a single conver-
sion result before proceeding to the next channel. The
MAX1400 automatically allows sufficient time for each
conversion to fully settle, to ensure optimum resolution
before asserting the data-ready signal and moving to
the next available channel. The scan rate is, therefore,
dependent on the clock bit (CLK), the filter control bits
(FS1, FS0), and the modulator frequency selection bits
(MF1, MF0).
Burnout Currents
The input circuitry also provides two “burnout” currents.
These small currents may be used to test the integrity
of the selected transducer. They can be selectively
enabled or disabled by the BOUT bit in the global
setup register.
CHANNEL
CID2
1
1
AIN1–AIN2
AIN5–AIN6
1
Calibration
1
1
0
1
1
AIN3–AIN4
1
0
0
0
0
0
AIN1–AIN6
AIN3–AIN6
0
AIN4–AIN6
1
1
0
1
0
AIN2–AIN6
1
0
CID0
0
CID1
0
Table 12. Input Channel Configuration in Fully and Pseudo-Differential Modes
(SCAN = 0)
X = Don’t care
*
This combination is available only in pseudo-differential mode when using the internal scanning logic
**
These combinations are only available in the calibration modes.
0
M0
0
DIFF
0
0
AIN2
0
0
0
0
0
AIN4
0
AIN3
AIN1
0
0
0
1
0
1
AIN3
0
0
1
1
X
CALOFF+**
0
AIN5
AIN1
0
0
0
X
1
X
CALOFF+**
M1
0
0
X
HIGH INPUT
CALGAIN+**
AIN5*
1
0
0
X
CALGAIN+**
1
0
A1
0
1
1
0
0
1
X
X
X
X
X
MODE
Pseudo-
Differential
Fully
Differential
0
A0
1
0
1
0
1
0
X
X
X
X
X
AIN6
AIN6
AIN6
AIN6
AIN4
CALOFF-**
AIN6
AIN2
CALOFF-**
LOW INPUT
CALGAIN-**
AIN6*
CALGAIN-**