beautypg.com

Table 11. channel id tag codes, Switching network – Rainbow Electronics MAX1400 User Manual

Page 20

background image

MAX1400

+5V, 18-Bit, Low-Power, Multichannel,
Oversampling (Sigma-Delta) ADC

20

______________________________________________________________________________________

Table 11. Channel ID Tag Codes

Switching Network

A switching network provides selection between three
fully differential input channels or five pseudo-differen-
tial channels, using AIN6 as a shared common. The
switching network provides two additional fully differen-
tial input channels intended for system calibration,
which may be used as extra fully differential signal
channels. Table 12 shows the channel configurations
available for both operating modes.

Scanning (SCAN-mode)

To sample and convert the available input channels
sequentially, set the SCAN control bit in the global
setup register. The sequence is determined by DIFF
(fully differential or pseudo-differential) and by the
mode control bits M1 and M0 (Tables 8, 9, 10). With
SCAN set, the part automatically sequences through
each available channel, transmitting a single conver-
sion result before proceeding to the next channel. The
MAX1400 automatically allows sufficient time for each
conversion to fully settle, to ensure optimum resolution
before asserting the data-ready signal and moving to
the next available channel. The scan rate is, therefore,
dependent on the clock bit (CLK), the filter control bits
(FS1, FS0), and the modulator frequency selection bits
(MF1, MF0).

Burnout Currents

The input circuitry also provides two “burnout” currents.
These small currents may be used to test the integrity
of the selected transducer. They can be selectively
enabled or disabled by the BOUT bit in the global
setup register.

CHANNEL

CID2

1

1

AIN1–AIN2

AIN5–AIN6

1

Calibration

1

1

0

1

1

AIN3–AIN4

1

0

0

0

0

0

AIN1–AIN6

AIN3–AIN6

0

AIN4–AIN6

1

1

0

1

0

AIN2–AIN6

1

0

CID0

0

CID1

0

Table 12. Input Channel Configuration in Fully and Pseudo-Differential Modes
(SCAN = 0)

X = Don’t care

*

This combination is available only in pseudo-differential mode when using the internal scanning logic

**

These combinations are only available in the calibration modes.

0

M0

0

DIFF

0

0

AIN2

0

0

0

0

0

AIN4

0

AIN3

AIN1

0

0

0

1

0

1

AIN3

0

0

1

1

X

CALOFF+**

0

AIN5

AIN1

0

0

0

X

1

X

CALOFF+**

M1

0

0

X

HIGH INPUT

CALGAIN+**

AIN5*

1

0

0

X

CALGAIN+**

1

0

A1

0

1

1

0

0

1

X

X

X

X

X

MODE

Pseudo-

Differential

Fully

Differential

0

A0

1

0

1

0

1

0

X

X

X

X

X

AIN6

AIN6

AIN6

AIN6

AIN4

CALOFF-**

AIN6

AIN2

CALOFF-**

LOW INPUT

CALGAIN-**

AIN6*

CALGAIN-**