DS1340

2-Wire RTC with Trickle Charger

2

_____________________________________________________________________

ABSOLUTE MAXIMUM RATINGS

Stresses beyond those listed under “Absolute Maximum Ratings” may cause permanent damage to the device. These are stress ratings only, and functional
operation of the device at these or any other conditions beyond those indicated in the operational sections of the specifications is not implied. Exposure to
absolute maximum rating conditions for extended periods may affect device reliability.

Voltage Range on V

CC

Pin Relative to Ground .....-0.3V to +6.0V

Voltage Range on SDA, SCL, and FT/OUT

Relative to Ground..................................-0.3V to (V

CC

+ 0.3V)

Operating Temperature Range ...........................-40°C to +85°C

Storage Temperature Range .............................-55°C to +125°C
Soldering Temperature Range ..................................See JEDEC

J-STD-020A Specification

AC ELECTRICAL CHARACTERISTICS

(V

CC

= V

CC MIN

to V

CC MAX

, T

A

= -40°C to +85°C, unless otherwise noted.) (Note 1, Figure 1)

PARAMETER

SYMBOL

CONDITIONS

MIN

TYP

MAX

UNITS

Standard mode

0

100

SCL Clock Frequency

f

SCL

Fast mode

100

400

kHz

Standard mode

4.7

Bus Free Time Between STOP
and START Conditions

t

BUF

Fast mode

1.3

µs

Standard mode

4.0

Hold Time (Repeated) START
Condition (Note 2)

t

HD:STA

Fast mode

0.6

µs

Standard mode

4.7

Low Period of SCL Clock

t

LOW

Fast mode

1.3

µs

Standard mode

4.0

High Period of SCL Clock

t

HIGH

Fast mode

0.6

µs

Standard mode

0

0.9

Data Hold Time (Notes 3, 4)

t

HD:DAT

Fast mode

0

0.9

µs

Standard mode

250

Data Setup Time (Note 5)

t

SU:DAT

Fast mode

100

ns

Standard mode

4.7

START Setup Time

t

SU:STA

Fast mode

0.6

µs

Standard mode

20 + 0.1C

B

1000

Rise Time of SDA and SCL
Signals (Note 6)

t

R

Fast mode

20 + 0.1C

B

300

ns

Standard mode

20 + 0.1C

B

300

Fall Time of SDA and SCL Signals
(Note 6)

t

F

Fast mode

20 + 0.1C

B

300

ns

Standard mode

4.7

Setup Time for STOP Condition

t

SU:STO

Fast mode

0.6

µs

Capacitive Load for Each Bus
Line

C

B

(Note 6)

400

pF

Pulse Width of Spikes that Must
be Suppressed by the Input Filter

t

SP

Fast mode

30

ns

Oscillator Stop Flag (OSF) Delay

t

OSF

(Note 7)

100

ms