3 environmental requirements, 1 temperature range, 2 vibration test (non functional) – Rainbow Electronics GE863-PRO3 User Manual
Page 14: 3 rohs compliance

GE863-PRO
3
Product Description
80285ST10036a
Rev. 1 - 08/08/08
Reproduction forbidden without Telit Communications S.p.A. written authorization - All Rights Reserved
page 14 of 55
2.3 Environmental requirements
The
Telit GE863-PRO
3
module
is compliant to the applicable ETSI reference documentation GSM 05.05
Release1998.
2.3.1 Temperature range
GE863-PRO
3
Note
Operating Temperature
Range
–20°C
÷ +55°C
The module is fully
functional(*) in all the
temperature range, and it fully
neets the ETSI specification
–30°C
÷ +85°C
The module is fully functional
(*) in all the temperature
range. Temperatures outside
the range –20°C ÷ +55°C,
might slightly deviate from
ETSI specifications.
Storage and Non Operating
Temperature Range
–40°C
÷ +85°C
(*) Functional: the module is able to make and receive voice calls, data calls, SMS and make GPRS traffic.
2.3.2 Vibration Test (non functional)
• 10
÷12Hz
ASD = 1.92m 2 /s 3
• 12
÷ 150Hz
–3dB/oct
2.3.3 RoHS compliance
The Telit GE863-PRO
3