ELECTRICAL CHARACTERISTICS (continued)
(V
CC
= +3.0V to +5.5V, V
STBY
= V
CC
, T
A
= -40°C to +125°C, unless otherwise noted. Typical values are at V
CC
= +3.3V and
T
A
= +25°C.) (Note 1)
PARAMETER
SYMBOL
CONDITIONS
MIN
TYP
MAX
UNITS
SMBus INTERFACE (SCL, SDA), STBY
Logic-Input Low Voltage
V
IL
0.8
V
V
CC
= 3.0V
2.2
Logic-Input High Voltage
V
IH
V
CC
= 5.0V
2.4
V
Input Leakage Current
-1
+1
µA
Output Low Voltage
V
OL
I
SINK
= 6mA
0.3
V
Input Capacitance
C
IN
5
pF
SMBus-COMPATIBLE TIMING (Figures 3 and 4) (Note 2)
Serial-Clock Frequency
f
SCL
(Note 3)
400
kHz
f
SCL
= 100kHz
4.7
Bus Free Time Between STOP
and START Condition
t
BUF
f
SCL
= 400kHz
1.6
µs
f
SCL
= 100kHz
4.7
START Condition Setup Time
f
SCL
= 400kHz
0.6
µs
90% of SCL to 90% of SDA,
f
SCL
= 100kHz
0.6
Repeat START Condition Setup
Time
t
SU:STA
90% of SCL to 90% of SDA,
f
SCL
= 400kHz
0.6
µs
START Condition Hold Time
t
HD:STA
10% of SDA to 90% of SCL
0.6
µs
90% of SCL to 90% of SDA,
f
SCL
= 100kHz
4
STOP Condition Setup Time
t
SU:STO
90% of SCL to 90% of SDA,
f
SCL
= 400kHz
0.6
µs
10% to 10%, f
SCL
= 100kHz
1.3
Clock Low Period
t
LOW
10% to 10%, f
SCL
= 400kHz
1.3
µs
Clock High Period
t
HIGH
90% to 90%
0.6
µs
f
SCL
= 100kHz
300
Data Hold Time
t
HD:DAT
f
SCL
= 400kHz (Note 4)
900
ns
f
SCL
= 100kHz
250
Data Setup Time
t
SU:DAT
f
SCL
= 400kHz
100
ns
f
SCL
= 100kHz
1
Receive SCL/SDA Rise Time
t
R
f
SCL
= 400kHz
0.3
µs
Receive SCL/SDA Fall Time
t
F
300
ns
Pulse Width of Spike Suppressed
t
SP
0
50
ns
SMBus Timeout
t
TIMEOUT
SDA low period for interface reset
25
37
45
ms
Note 1: All parameters are tested at T
A
= +85°C. Specifications over temperature are guaranteed by design.
Note 2: Timing specifications are guaranteed by design.
Note 3: The serial interface resets when SCL is low for more than t
TIMEOUT
.
Note 4: A transition must internally provide at least a hold time to bridge the undefined region (300ns max) of SCL’s falling edge.