beautypg.com

Table 8. status 2 register, Table 9. status 3 register – Rainbow Electronics MAX6636 User Manual

Page 15

background image

MAX6636

7-Channel Precision Temperature Monitor

______________________________________________________________________________________

15

BIT

NAME

POR

STATE

FUNCTION

7 (MSB)

Reserved

0

6

Reserved

0

5

Remote 6 OVERT

0

Channel 6 Remote-Diode Overtemperature Status Bit. This bit is set to logic 1
when the channel 6 remote-diode temperature exceeds the temperature
threshold limit in the remote 6 OVERT high-limit register.

4

Remote 5 OVERT

0

Channel 5 Remote-Diode Overtemperature Status Bit. This bit is set to logic 1
when the channel 5 remote-diode temperature exceeds the temperature
threshold limit in the remote 5 OVERT high-limit register.

3

Remote 4 OVERT

0

Channel 4 Remote-Diode Overtemperature Status Bit. This bit is set to logic 1
when the channel 4 remote-diode temperature exceeds the temperature
threshold limit in the remote 4 OVERT high-limit register.

2

Reserved

0

1

Reserved

0

0

Remote 1 OVERT

0

Channel 1 Remote-Diode Overtemperature Status Bit. This bit is set to logic 1
when the channel 1 remote-diode temperature exceeds the temperature
threshold limit in the remote 1 OVERT high-limit register.

Table 8. Status 2 Register

BIT

NAME

POR

STATE

FUNCTION

7 (MSB)

Reserved

0

6

Diode fault 6

0

Channel 6 Remote-Diode Fault Bit. This bit is set to 1 when DXP6 and DXN6
are open circuit or when DXP6 is connected to V

CC

.

5

Diode fault 5

0

Channel 5 Remote-Diode Fault Bit. This bit is set to 1 when DXP5 and DXN5
are open circuit or when DXP5 is connected to V

CC

.

4

Diode fault 4

0

Channel 4 Remote-Diode Fault Bit. This bit is set to 1 when DXP4 and DXN4
are open circuit or when DXP4 is connected to V

CC

.

3

Diode fault 3

0

Channel 3 Remote-Diode Fault Bit. This bit is set to 1 when DXP3 and DXN3
are open circuit or when DXP3 is connected to V

CC

.

2

Diode fault 2

0

Channel 2 Remote-Diode Fault Bit. This bit is set to 1 when DXP2 and DXN2
are open circuit or when DXP2 is connected to V

CC

.

1

Diode fault 1

0

Channel 1 Remote-Diode Fault Bit. This bit is set to 1 when DXP1 and DXN1
are open circuit or when DXP1 is connected to V

CC

.

0

Reserved

0

Table 9. Status 3 Register