Output page, Full range limiter – TC Electronic MD3 TDM User Manual
Page 19
MD3-TDM
/ 17
EE
NN
GG
LL
II
SS
HH
Output page
FULL RANGE LIMITER
Soft clip
Range: -6dB to 0 dB in 1-dB-steps; +3dB; off.
Soft clipper after the Compressor.
Threshold is relative to 0dBFS - not to the Ref Level.
Threshold
Threshold is relative to 0dBFS - not to the Ref Level.
Range: -12 to +3 dB
-6 to + 3 in 0.1dB increments
-12 to -6 in 0.5dB increments
Release
Range: 20ms to 7sec
Release time for the Limiter.