Page 16
EE
NN
GG
LL
II
SS
HH
14 /
MD3-TDM
Attack
Range: 0.3 to 100ms (Exponential)
The Attack time is the time the Expander uses to release its gain reduction when the
Input signal rises above the set Threshold point.
Release
Range: 20ms to 7sec. (Exponential)
The Release time is the time the Expander uses to achieve the attenuation
specified by the Ratio parameter when the signal drops below the set Threshold point.
Meter Zoom
Press to zoom on the range of the Gain Reduction meters.
L/R