beautypg.com

TC Electronic MD3 TDM User Manual

Page 16

background image

EE

NN

GG

LL

II

SS

HH

14 /

MD3-TDM

Attack

Range: 0.3 to 100ms (Exponential)
The Attack time is the time the Expander uses to release its gain reduction when the
Input signal rises above the set Threshold point.

Release

Range: 20ms to 7sec. (Exponential)
The Release time is the time the Expander uses to achieve the attenuation
specified by the Ratio parameter when the signal drops below the set Threshold point.

Meter Zoom

Press to zoom on the range of the Gain Reduction meters.

L/R

Press to view all algorithm parameters at the same time.