Topdry, U.s measurements, Metric measurements – Grain Systems PNEG-566 User Manual
Page 6

6
TOPDRY
Prices and Specifications subject to change without notice. • 888-GSI-BINS • Fax 800-800-5329 • www.gsiag.com
April 4, 2011
U.S Measurements
(Shelled Corn)
Bin
Diameter
Batch Size
(BU)
Grain in
Process
(BU)
Dump Size
(BU)
Rings
Eave
Height
Peak
Height
Maximum
Storage
(BU)
Maximum
Storage
(BU)
Batch
Autoflow
Batch
Autoflow
24’
1,000
560
187
5
18’-5”
25’-0”
4,813
4,373
6
22’-1”
28’-8”
6,198
5,758
7
25’-9”
32’-4”
7,583
7,143
8
29’-5”
36’-0”
8,968
8,528
9
33’-1”
39’-8”
10,353
9,913
10
36’-9”
43’-4”
11,738
11,298
30’
1,500
845
282
5
18’-5”
26’-9”
7,459
6,804
6
22’-1”
30’-5”
9,623
8,968
7
25’-9”
34’-1”
11,787
11,132
8
29’-5”
37’-9”
13,951
13,296
9
33’-1”
41’-5”
16,115
15,460
10
36’-9”
45’-1”
18,279
17,624
11
40’-5”
48’-9”
20,443
19,788
36’
2,160
1,215
405
6
22’-1”
32’-6”
13,859
12,914
7
25’-9”
36’-2”
16,974
16,029
8
29’-5”
39’-10”
20,089
19,144
9
33’-1”
43’-6”
23,204
22,259
10
36’-9”
47’-2”
26,319
25,374
11
40’-5”
50’-10”
29,434
28,489
Metric Measurements
(Shelled Corn)
Bin
Diameter
Batch Size
(MT)
Grain in
Process
(MT)
Dump Size
(MT)
Rings
Eave
Height
Peak
Height
Maximum
Storage
(MT)
Maximum
Storage
(MT)
Batch
Autoflow
Batch
Autoflow
7.32 m
(24’)
25.4
14.22
4.75
5
5.61 m 7.62 m
122.25
111.07
6
6.73 m 8.74 m
157.43
146.25
7
7.85 m 9.86 m
192.61
181.43
8
8.97 m 10.97 m
227.79
216.61
9
10.08 m 12.09 m
262.97
251.79
10
11.20 m 13.21 m
298.15
286.97
9.14 m
(30’)
38.1
21.46
7.16
5
5.61 m 8.15 m
189.46
172.82
6
6.73 m 9.27 m
244.42
227.79
7
7.85 m 10.39 m
299.39
282.75
8
8.97 m 11.51 m
354.36
337.72
9
10.08 m 12.62 m
409.32
392.68
10
11.20 m 13.74 m
464.28
447.65
11
12.32 m 14.86 m
519.25
502.61
10.97 m
(36’)
54.86
30.86
10.29
6
6.73 m 9.91 m
352.02
328.02
7
7.85 m 11.02 m
431.14
407.14
8
8.97 m 12.14 m
510.26
486.26
9
10.08 m 13.26 m
589.38
565..38
10
11.20 m 14.38 m
668.50
644.50
11
12.32 m 15.49 m
747.63
723.62
Note: Maximum storage is estimated with 12” aeration floor, level to bottom of fan entrance, with upper batch filled.