Pilot gas solenoid (n.c.), Downsteam maxon shutoff valve modutrol motor, Power box terminal strip – Grain Systems PNEG-554 User Manual
Page 39: Upsteam maxon shutoff valve

39
GSI TOWER DRYER WIRING DIAGRAMS
STANDARD FUEL TRAIN WIRING
PILOT GAS
SOLENOID
(N.C.)
R
R
G
1
2
3
4
5
6
7
8
9
10
11
12
DOWNSTEAM MAXON
SHUTOFF VALVE
MODUTROL MOTOR
T1
T2
(-)
(+)
F
B
W
J5-8
J3-4
J9-9
J7-6
MAXON
J7-4
J7-17
J7-7
4-20C
4-20D
(RED)
(YELLOW)
(BROWN)
(WHITE)
(BLACK)
(BLACK SHIELD)
(WHITE SHIELD)
(WHITE)
(ORANGE)
(WHITE)
POWER BOX
TERMINAL STRIP
1
2
3
4
5
6
7
8
9
10
11
12
UPSTEAM MAXON
SHUTOFF VALVE
See also other documents in the category Grain Systems Conditioners:
- PNEG-1890 (16 pages)
- PNEG-595 (26 pages)
- PNEG-1472 (30 pages)
- PNEG-897 (58 pages)
- PNEG-838 (4 pages)
- PNEG-1755 (36 pages)
- PNEG-524 (24 pages)
- PNEG-1080 (2 pages)
- PNEG-728 (47 pages)
- PNEG-673 (57 pages)
- PNEG-1717 (88 pages)
- PNEG-823 (42 pages)
- PNEG-630-6S (23 pages)
- PNEG-1876 (80 pages)
- PNEG-102 (2 pages)
- PNEG-366 (51 pages)
- PNEG-1626 (1 page)
- PNEG-1874 (78 pages)
- PNEG-1798 (34 pages)
- PNEG-1927 (4 pages)
- PNEG-924 (2 pages)
- PNEG-582 (26 pages)
- PNEG-012 (46 pages)
- PNEG-1797 (86 pages)
- PNEG-546 (26 pages)
- PNEG-951 (102 pages)
- PNEG-1650 (92 pages)
- PNEG-1649 (50 pages)
- PNEG-1376 (88 pages)
- PNEG-361 (46 pages)
- PNEG-338 (32 pages)
- PNEG-1276 (78 pages)
- PNEG-1283 (22 pages)
- PNEG-1089 (14 pages)
- QSG-001 (2 pages)
- PNEG-950 (96 pages)
- PNEG-1590 (3 pages)
- PNEG-501 (33 pages)
- PNEG-1447 (68 pages)
- PNEG-707GSI (446 pages)
- PNEG-349 (32 pages)
- PNEG-236 (22 pages)
- PNEG-743 (16 pages)
- PNEG-900 (54 pages)
- PNEG-1935 (92 pages)