beautypg.com

14 ga), Chapter 6: stiffeners – Grain Systems Tanks PNEG-4078 User Manual

Page 57

background image

Chapter 6: Stiffeners

Close-Punch Two-Ring Stiffener (2–14 Ga) to a Laminated Stiffener
(2 Ga) with an Insert (10–14 Ga)

Reference the following information for a close-punch connection with a two-ring stiffener (CTS-2073XX)
to a laminated stiffener (CTS-2114XX) and insert (CTS-2113XX).

Figure 6-19 Close-Punch Two-Ring Stiffener to a Laminated Stiffener with an Insert

A

Close-punch two-ring stiffener (CTS-2073XX)

B

Close-punch laminated stiffener
(CTS-2114XX)

C

Insert (CTS-2113XX)

D

3/8 x 1 Bolt (S-7485)

E

3/8 Nut (S-9426)

F

Completed assembly

NOTE: Two-post stiffeners shown. The bolt pattern will

vary for three-post. Only place bolts where
holes in the stiffeners align with holes in the
sidewall sheet.

Close-Punch Laminated Stiffeners (2 Ga) with Inserts (10–14 Ga)

Reference the following information for a close-punch connection of a laminated stiffener (CTS-2079XX) to
a laminated stiffener (CTS-2081XX).

Figure 6-20 Close-Punch Laminated Stiffeners with Inserts

A

Close-punch laminated stiffener
(CTS-2079XX)

B

Close-punch insert (CTS-2081XX)

C

3/8 x 1 Bolt (S-7485)

D

3/8 Nut (S-9426)

E

Completed assembly

NOTE: Two-post stiffeners shown. The bolt pattern will

vary for three-post. Only place bolts where
holes in the stiffeners align with holes in the
sidewall sheet.

Pneg-4078 78 Ft Diameter 40-Series Bin

57