Chapter 7: roof assembly – Grain Systems Tanks PNEG-4078 User Manual
Page 104
1. With assistance, position a lower roof panel (A) onto the first rafter in any A-frame.
2. Install five flange bolts (D) and five flange nuts (E) into the lower portion of the lower roof panel secur-
ing the lower roof panel to the eave angle.
3. With assistance, position another lower roof panel (A) onto the next rafter in the A-frame.
NOTE: There should be an exposed gap between the two lower roof panels in the A-frame.
4. Install five flange bolts (D) and five flange nuts (D) into the lower portion of the lower roof panel secur-
ing the lower roof panel to the eave angle.
Figure 7-27 Installing the lower roof panels
A
Lower roof panel (CTR-0268)
E
5/16 in. flange nut (S-3611)
D
5/16-18 x 1 flange bolt with sealing washer
(S-10260)
5. After installing the two lower roof panels onto the A-frame rafters, with assistance, position an upper
roof panel (C) onto a A-frame rafter (F).
6. Install a flange bolt (D) and a flange nut (E) to secure the upper roof panel (C) to the rafter (F).
7. With assistance, position another upper roof panel (C) onto the next rafter in the A-frame.
104
Pneg-4078 78 Ft Diameter 40-Series Bin