Chapter 7: Roof Assembly

IMPORTANT: For adjustment purposes, DO NOT tighten the X-brace flange bolts until all X-braces

have been installed.

5. Attach the top X-brace (J) to the left-hand roof rafter (A), and install a flange bolt (F) and one flange

nut (I) into the top hole.

6. Secure the bottom portion of each X-brace (J and K) with a flange bolt (F) and one flange nut (I).

7. Install a flange bolt (L) and one flange nut (M) securing the X-braces together where they cross.

8. After all purlins are installed, tighten the hardware to the recommended torque specifications. See

Bolt Torque Specifications, page 24

.

Pneg-4090 90 Ft Diameter 40-Series Bin

91