Chapter 7: Roof Assembly

7. Install a flange bolt (L) and one flange nut (M) securing the X-braces together where they cross.

8. After all purlins are installed, tighten the hardware to the recommended torque specifications. See

Bolt Torque Specifications, page 24

.

Figure 7-15 Purlin location 4

A

Left-hand roof rafter (CTR-0012)

H

Purlin (CTR-0008)

B

1/2 x 1-3/4 in. flange bolt (S-10252)

I

1/2 in. flange nut (S-10253)

C

Right-hand roof rafter (CTR-0012)

J

Top X-brace (CTR-0038)

Pneg-4090 90 Ft Diameter 40-Series Bin

89