beautypg.com

Chapter 7: roof assembly – Grain Systems Tanks PNEG-4090 User Manual

Page 87

background image

Chapter 7: Roof Assembly

Figure 7-14 Purlin location 5

A

Left-hand roof rafter (CTR-0012)

H

Purlin (CTR-0009)

B

1/2 x 1-3/4 in. flange bolt (S-10252)

I

1/2 in. flange nut (S-10253)

C

Right-hand roof rafter (CTR-0012)

J

Top X-brace (CTR-0040)

D

Right purlin clip (CTR-0100)

K

Bottom X-brace (CTR-0040)

E

Left purlin clip (CTR-0099)

L

1/2 x 1-3/4 in. flange bolt (S-10252)

Pneg-4090 90 Ft Diameter 40-Series Bin

87