beautypg.com

Temperature cable layout – Grain Systems Tanks PNEG-2135 User Manual

Page 73

background image

10. 2.66" Commercial Tank Accessories Installation

PNEG-2135 Construction Manual for 2.66" Corrugation 135' Diameter Tank

73

Temperature Cable Layout

Figure 10K

shows the GSI recommendation for the 135' commercial bin temperature cable layout, based

on a temperature cable manufacturer’s system. This detail is provided solely for the purpose of facilitating
proper support bracket placement. It is fully the responsibility of the dealer, customer, contractor or
said agent of such parties to confirm details of the system to be used. GSI is not responsible for the
effectiveness or performance of any temperature cable monitoring system or layout.

Note that the roof is designed for cables on a radius of 10', 32' and 55'. A maximum of one temperature
cable should hang from each beam. There are a total of forty five (45) beams which results in a maximum
of forty five (45) temperature cables. The layout shown includes thirty four (34) temperature cables;
four (4) cables are on a 10' radius, fifteen (15) cables on a 32' radius and fifteen (15) cables on a 55'
radius. See chart

on Page 74

for tabled layout. Any variation from this pattern or cable quantity

above forty five (45) must be reviewed by GSI. This must be reviewed well in advance of the start of
roof construction.

See Figure 10L on Page 75

for temperature cable bracket installation instructions.

Figure 10K GSI 135' Diameter Temperature Cable Layout