HIGH TEMPERATURE 10-15hp 7/32" orifice
OPERATING PRESSURE (PSI)
2
4
6
8
10
12
14
15
ALL
MODELS
816013
1148640
1409477
1632026
1825859
1995762
2153700
2227883
Static
Fan Model
Pressure
60
80
100
120
140
160
180
2"
2
4
6
8
10
13
10HP
4"
1
3
5
6
8
11
14
6"
1
1
3
5
6
8
10
2"
3
6
9
12
15
15HP
4"
3
5
7
10
13
6"
2
3
5
6
9
11
14
Gauge Pressure (Psi) Required To Maintain Temperature ( Approximate )
( 10-15 Horsepower High Temp Propane Units Only )
Heat Rise Degrees F
Static
Fan Model
Pressure
60
80
100
120
140
160
180
2"
1
1.75
2.5
3.5
4.75
6
10HP
4"
0.75
1.25
2
2.75
3.75
4.75
6
6"
0.5
1
1.5
2
2.75
3.5
4.25
2"
1.5
2.5
3.75
5.5
15HP
4"
1.25
2
3
4.25
5.75
6"
0.75
1.25
2
2.75
3.75
5
6
( 10-15 Horsepower High Temp Natural Gas Units Only )
Heat Rise Degrees F
Gauge Pressure (Psi) Required To Maintain Temperature ( Approximate )
BTU’s Per Gauge Pressure (PSI)
PROPOANE MODELS
(Approximate)
BTU’s Per Gauge Pressure (PSI)
NATURAL GAS MODELS
(Approximate)
1
2
3
4
5
6
7
ALL
MODELS
859104
1218432
1489296
1718208
1921584
2107632
2276352
HIGH TEMPERATURE 10-15hp 11/32” orifice
OPERATING PRESSURE (PSI)
OPERATING PROCEDURE