Setting the Moisture Control and Plenum Setpoint
1. Press the Program (Temperatures) button until the carrot is under the temperature setting to
be changed.
2. Use the UP and DOWN arrow keys to change from the present temperature to the new one. The new
time is automatically entered.
3. Keep pressing the Program (Temperatures) button until the carrot disappears or press the Mode
Select button once to exit.
Dryer Safety Circuit
The Series 2000 Control System continuously checks all safety circuits on the dryer and will automatically
shut the dryer down should a problem occur. The cause of the dryer shutdown will be shown on the LCD
display. To restart the dryer after a safety shutdown, first correct the reason for the shutdown and then
press the Dryer Power Stop button to reset the circuit. Press the Start button.
Figure 1D Series 2000 Control System
Monitoring Grain Temperatures, Plenum Temperature or Timers
Use the mode select to decide which of the modes you want to view.
Checking the Hour Meter
Press the UP arrow key and the total hours on the machine are displayed along with the batch count and
minutes since the last shutdown in five (5) successive screens. The screens appear in the following order:
Hours X 100, balance of hours, balance of minutes, batch count and minutes since last shutdown.
For example, five (5) screens displaying 5 | 23 | 12 | 144 | 188 would be: 523 Hours, 12 minutes on the
Hour Meter, Batch Count at 144 and 188 minutes since the last shutdown.
MOISTURE CONTROL SET POINT
POINT DE CONSIGNE DU CONTRÔLE D’HUMIDITÉ
PLENUM TEMPERATURE SET POINT
POINT DE CONSIGNE DE TEMP DE PLÉNUM
HI LO SPEED
VITESSE HAUTE LENTE
DISCHARGE
DÉCHARGE
LO-FLAME
FLAMME BASSE
HI-FLAME
FLAMME HAUTE
PURGE
PURGE
MOTOR
MOTEUR
OVERLOAD
SURCGARGE
ERROR
ERREUR
NO AIRFIOW
PAS D’ÉCOULEMENT D’AIR
% GRAIN
% GRAIN
°F PLENUM
PLÉNUM F
°C HOUSING
BOITÎER C
VAPOR
VAPEUR
TEMP HI-LIMIT
TEMP LIM-ÉLEVÉE
FLAME OUT
FLAMME ÉTEINTE
PROGRAM
(TIMERS)
PROGRAMME
(MINUTERIES)
PROGRAM
(TEMPERATURES)
PROGRAMME
(TEMPÉRATURES)
PROGRAM
(DELAYS)
PROGRAMME
(DÉLAIS)
MODE SELECT
TIMERS/PLENUM TEMP/
GRAIN TEMP
MODE CHOISI (SELECT)
MINUTERIES/TEMP PLÉNUM/
TEMP GRAIN
HOURS
X 1000
HEURES
X 1000
HOURS
HEURES
DC-2004
LOAD DELAY
DÉLAI DE CHARGE
DRY TIME
TEMPS DE SÉCHAGE
OUT OF GRAIN TIME
TEMPS HORS GRAIN
COOL TIME
TEMPS DE REFROIDISSEMENT
UNLOAD TIME
TEMPS DE DÉCHARGE
UNLOAD DELAY
DÉLAI DE DÉCHARGE