In chart, Is reached, Are pro – Grain Systems PNEG-1856 User Manual
Page 2: Baldor motor kit

Page 2 of 9
PNEG-1856
Baldor Motor Kit
Programming Baldor H2 and VS Drives on Dryers Built 1993 and
Prior or 1998 and UP (Continued)
All parameters and their settings to be changed for Zimmerman purposes shown in chart
.
NOTE: After programming is complete if local is displayed in upper right hand corner of status screen.
Then Local/Remote button will have to be pressed to change to remote. This is a one time
operation and will not have to be done in the future.
* NOTE: Accutrol Unload Dryers Only - 5 amps is selected for 17' diameter dryers, 6 amps for
23'-4" diameter dryers. Dryers with metering augers stay at factory setting.
Top Level
Programming Menu
1
st
Level
Parameter Group
Individual
Parameters
Settings
Zimmerman Changes
Level 1 Blocks
Ramp Rates
Accel Time #1
3 Seconds
Decel Time #1
3 Seconds
Level 1 Blocks
Keypad Setup
Stop Key
OFF
Stop Mode
Coast
Run Forward
OFF
Run Reverse
OFF
Level 1 Blocks
Input Setup
Operating Mode
Standard Run 3 Wire
Command Source
Analog In1
Analog In1 Type
Potentiometer
Level 1 Blocks
Output Setup
Analog Out 1 Type
0-5V
Level 2 Blocks
Drive Limits
Minimum Output Speed
7 Hertz
Maximum Output Speed
75 Hertz
Level 2 Blocks
Drive Protect
External Trip
ON
Level 2 Blocks
Motor Data
Motor Rated Amps
Factory/5 Amps or 6 Amps*
Press R to Exit
Press R to Exit
Press R to Exit
Press ENTER at Status