Series 2000 heater installation, Fuel connection – Grain Systems PNEG-582 User Manual
Page 12

12
SERIES 2000 HEATER INSTALLATION
Standard electrical safety prac-
tices and codes should be
used when working with a
heater. Refer to the National
Electric Code Standard Hand-
book by the National Fire Pro-
tection Association. A quali-
fied electrician should make all
wiring installations.
IMPORTANT! Do not use pro-
pane tanks that have previ-
ously been used for ammonia
unless they have been purged
according to procedures of the
National L.P. Association.
Fuel supply system must
comply with local codes for L.P.
gas installation.
1. Propane vapor models are de-
signed to run directly off of a
supply tank or from a separate
external vaporizer.
2. Run proper size line (see speci-
fications on page 6) to pipe train
on heater. Have a qualified gas
service person inspect installa-
tion to be sure that everything
is installed according to local
codes and ordinances.
3. After installation is complete
check all connections for leaks.
DO NOT USE FLAME FOR
LEAK TESTING.
LIQUID PROPANE
MODELS
NATURAL GAS MODELS
PROPANE VAPOR
MODELS
ALWAYS DISCONNECT
AND LOCK OUT
POWER
BEFORE WORKING ON
OR AROUND HEATER
1. Natural gas models are de-
signed to run directly off of a
supply tank or from a separate
external vaporizer.
2. Run proper size line (see speci-
fication on page 6) to pipe train
on heater. Have a qualified gas
service person inspect installa-
tion to be sure everything is in-
stalled according to local codes
and ordinances.
3. After installation is complete
check all connections for leaks.
DO NOT USE FLAME FOR
LEAK TESTING.
3. After installation is complete
check all connections for leaks
with liquid detergent or compa-
rable. Wear rubber gloves and
eye protection. Avoid contact
with liquid propane. DO NOT
USE FLAME FOR LEAK TEST-
ING.
1. L.P. models are designed to run
on liquid propane with liquid
draw from the propane tank.
Avoid using propane supply
tanks that have been used for
vapor draw for long periods of
time. When using liquid draw
systems any moisture that may
be present in tank or lines may
freeze when system is used in
cold weather. To avoid this situ-
ation, purge the system with
methanol.
2. Run proper size line (see speci-
fication on page 6) to liquid pipe
train on heater. Have a qualified
gas service person inspect in-
stallation to be sure that every-
thing is installed according to
local codes and ordinances.
FUEL CONNECTION