Installation, Chapter 4 installation, Heater specifications plenum thermostat mounting – Grain Systems PNEG-823 User Manual
Page 13: Heater specifications, Plenum thermostat mounting
PNEG-823 Deluxe Downwind Heater
13
4. Installation
Heater Specifications
Centrifugal Heater Specifications
Heater Dimensional Specifications
Plenum Thermostat Mounting
The plenum thermostat is the 4 x 4 white box with knob that is preconnected to heater when heater is
ordered with thermostat.
1. 24" to the right side of the transition, drill one (1) 3/8" hole (High-Temperature) or 1-1/2" hole
(Low-Temperature) in the center of the plenum in a valley (4.00" corrugation) or hill
(2.66" corrugation) on bin sidewall.
2. Insert the probe through the hole.
3. Position the housing so that the tabs are vertical, and the cord exits the housing horizontally.
4. Use four (4) self-drilling screws to mount the housing to the bin sidewall.
5. Caulk between the housing and the sidewall to seal.
High-Temperature
Model
Low-Temperature
Model
All Models
BTU Rating
4000000
500000
Weight
145
135
Maximum Fuel Flow (GPH)
43
N/A
Orifice Size
0.25
N/A
Liquid Models
Minimum Operating Pressure
3
N/A
Maximum Operating Pressure
30
N/A
Minimum Line Size
3/8"
N/A
Vapor Models
Maximum Fuel Flow (CFH)
1590
210
Orifice Size
0.25
0.109
Minimum Operating Pressure
2
1
Maximum Operating Pressure
30
15
Minimum Line Size
1"
1/2"
Natural Gas Models
Maximum Fuel Flow (CFH)
4200
500
Orifice Size
0.375
0.156
Minimum Operating Pressure
1
1
Maximum Operating Pressure
15
7
Minimum Line Size
1-1/4"
1"
Heater Size
10-15
20-30
40
Inside Height
30-1/4"
33-1/4"
33-1/4"
Inside Width
19-1/2"
21-3/4"
23-11/16"
Inside Length
24"
24"
24"