Banks Power Ford Trucks: (Diesel ’99 - 03 7.3L Power Stroke) Tuner- Six-Gun Diesel Tuner '99-03 User Manual
Page 20
20
96454 v.9.0
NotE: the Banks Six-Gun tuner for
the Ford 7.3L Power Stroke engine
increases the fuel pressure to increase
performance. If the fuel system on your
Ford 7.3L Power Stroke engine cannot
supply the demanded fuel then an
engine code will be set. the engine code
set may be the P1211- (Injector Control
Pressure is different than expected). If
this occurs to you while driving then
select a lower Six-Gun power level and
continue to lower the power level until
you no longer set the engine code. the
code clears itself after several ignition
cycles.
The Six-Gun Diesel Tuner is equipped
with self-diagnosing features that
automatically check for proper sensor
and module operation. Error codes
that your module may display, either
upon startup or after accessing the
Diagnostics submenu, are listed below.
Section 4:
TROUBLESHOOTING
Table 2
Error Code
Code Description
Course of Action
BST ERR1
The Six-Gun module
has detected a fault in
the Manifold Absolute
Pressure (MAP) input
circuit.
The listed error code(s) will occur when the
Six-Gun module fails to receive any signal from
the associated sensor, or receives an input
signal from the sensor that is out of the normal
operating range.
Turn the vehicle and ignition completely off,
check the Six-Gun harness connections at the
sensor in question to ensure that they are fully
engaged. Also check the 2- and 6-pin connectors
at the back of the Six-Gun module to ensure
that they are properly engaged. After checking
all connections, restart the vehicle – if the Six-
Gun module continues to display the same error
message, please contact Banks Technical Service
ICP ERR2
The Six-Gun module
has detected a fault in
the Injection control
Pressure (IcP) input
circuit.
EGT ERR3
The Six-Gun module
has detected a fault
in the Exhaust Gas
Temperature (EGT)
input circuit.
BSTO ERR4
The Six-Gun module
has detected a fault in
the Manifold Absolute
Pressure (MAP) output
circuit.
The listed output error(s) will be displayed when
the Six-Gun module detects a problem with the
associated output signal.
Turn the vehicle and ignition completely off,
check the Six-Gun harness connections at the
sensor in question to ensure that they are fully
engaged. Also check the 6-pin connector at the
back of the Six-Gun module to ensure that it is
properly engaged. After checking all connections,
restart the vehicle – if the Six-Gun module
continues to display the same error message,
please contact Banks Technical Service.
ICPO ERR5
The Six-Gun module
has detected a fault in
the Injection control
Pressure (IcP) output
circuit.
INT ERR6
The Six-Gun module has
detected an internal
(module) error.
Turn the vehicle completely off then restart it – if
the error is still present contact Banks Technical
Service.