Factory reset
Password required
Command RES;pwd

pwd = current password (default = 12345)

Example RES;12345

Enable SMS reception
Password required
Command SMSxxxxxxxx:ON;pwd

xxxxxxxx = position of the number in the list (1~8)

pwd = current password (default = 12345)

Example SMS15:ON;12345
Result

Phone numbers on position 1 and 5 will receive an SMS when input status

changes. Other numbers are not affected. By default all eight phone numbers

receive an SMS.

Disable SMS reception
Password required
Command SMSxxxxxxxx:OFF;pwd

xxxxxxxx = position of the number in the list (1~8)

pwd = current password (default = 12345)

Example SMS27:OFF;12345
Result

Phone numbers on position 2 and 7 will NOT receive an SMS when input
status changes. Other numbers are not affected.

Enable ringtone reception
Password required
Command VOCxxxxxxxx:ON;pwd

xxxxxxxx = position of the number in the list (1~8)

pwd = current password (default = 12345)

Example VOC15:ON;12345
Result

Phone numbers on position 1 and 5 will receive a ringtone when input status

changes. Other numbers are not affected. By default all eight phone numbers

receive ringtones.

Disable ringtone reception
Password required
Command VOCxxxxxxxx:OFF;pwd

xxxxxxxx = position of the number in the list (1~8)

pwd = current password (default = 12345)

Example VOC36:OFF;12345
Result

Phone numbers on position 3 and 6 will NOT receive a ringtone when input

status changes. Other numbers are not affected.

Set logic alarm level to HIGH (alarm when input under tension)
Password
Command LIVx:A

x = 1 (input 1) or 2 (input 2)

Example LIV2:A
Result

Set alarm level on input 2 to high, alarm is activated when input 2 is under

tension. Default both inputs are set to level HIGH.