beautypg.com

Velleman HAMGSM133 User Manual

Page 13

background image

HAMGSM133

V. 02 – 15/05/2012

13

©Velleman nv

Request current setting of relay status backup
Password
Command RIP?
Example RIP?
Result

Get an overview of the current setting for the output relay backup.

Start-up SMS content
Password
Command TSU:xxxxxxxx

xxxxxxxx = message (max. 100 characters, all capitals)

Example

TSU: SYSTEM START-UP

Result

When enabled (see AVVx command), this message is send to phone number

on the first position in the list. Default: SYSTEM STARTUP

Note:

a semi colon (;) is not allowed inside the message

Activate start-up SMS
Password
Command AVVx

x = 0 (disabled) or 1 (enabled)

Example AVV1
Result

Enable sending an SMS to the phone number on the first position in the list

when the device is started or restarted. Default: 0 (disabled)

Gate control activation (relay 1)
Password
Command TAC:ss

ss = time in seconds (00~59)

Example TAC:12
Result

When receiving a call from any of the 200 gate control numbers or 8

numbers in the master list, the relay will remain activated for 12 seconds.

Default: 3 seconds

Note:

When setting the time to 00, the relay operates in bi-stable mode;

relay 1 will switch status every time the device receives a call.

Store gate control phone numbers (max. 200)
Password required
Command MAC+YYnnnnnnnnnn;pwd

YY= country code

nnnnnnnnnn = phone number (max. 19 digits)

pwd = current password (default = 12345)

Example MAC+324851234567;12345
Note:

There are no specific locations for gate control phone numbers.

Delete gate control phone numbers
Password required
Command DAC+YYnnnnnnnnnn;pwd

YY= country code

nnnnnnnnnn = phone number to delete

pwd = current password (default = 12345)

Example DAC+324851234567;12345

Disable reply SMS
Password
Command RISP

(commands)

Commands: series of commands separated by commas (,)

Example

RISP, OUT1:ON, DAC, INI1:10